Configuring BOSCH KBD-Digital or BOSCH KBD-Universal control panel in

...

Axxon PSIM™

Configure BOSCH KBD-Digital or BOSCH KBD-Universal control panel in INTELLECT Axxon PSIM™ as follows:

  1. Create the Telemetry Controller object.
  2. Configure the Telemetry Controller object as follows:

    1. Set the Bosch-IntuiKey interface protocol.

    2. Select the COM port in the Port list.

    3. Set 19200 value to the Speed parameter.

    4. Set the None value for the Parity parameter.

    5. Set the DTR and RTS checkboxes checked.

  3. Create the Control panel system object under the Telemetry Controller object.

  4. Configure the Control panel object as described in Configuring Control panel section.

BOSCH KBD-Digital or BOSCH KBD-Universal control panel is now configured in INTELLECT Axxon PSIM™.

Features of BOSCH KBD-Digital or BOSCH KBD-Universal control panel operation in

...

Axxon PSIM™

Note
titleAttention!

Before you start using BOSCH KBD-Digital or BOSCH KBD-Universal control panel in INTELLECT Axxon PSIM™, switch it to the Terminal mode. For this press the Prod key and select Terminal on the monitor.

...

When the key is pressed on BOSCH KBD-Digital or BOSCH KBD-Universal control panel there is Key is pressed or Key is released message in INTELLECT™Axxon PSIM™.

Event

Message

Parameter

Description

KEY_PRESSED

Key pressed

param0

Code of pressed key

KEY_RELEASED

Key released

param0

Code of released key

...