Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Parameter

Parameter value setting method

Parameter description

Representation

Default value

Range of values

1

Identification number field

Automatically

Displays the identification number of the Incident handler interface object in the system

Positive integers

-

Depends on the number of Incident handler objects in the system

2

Name field

Type-in the value in the field

Sets the name of the Incident handler object in the system

Latin, Cyrillic and service characters 

Incident handler

A string containing a sequence of any characters (letters, numbers, service characters except for > and <), case-insensitive.

Number of characters - from 1 to 60

3

Disable checkbox

Set the checkbox

Sets the state (enabled or disabled) of the Incident handler object in the system

Boolean type

No

Yes - the Incident handler object is disabled and not used

No - the Incident handler object is enabled and in use

4Incident server drop-down list

Select from the list

Specifies the parent Incident server object for this Incident handler objectNames of Incident server objects registered in the system Name of the parent Incident server objectDepends on the number of Incident server objects in the system
Filters tab

5

Type drop-down list

Select from the list

Sets the type of objects for which the events should be displayed in the Incident handler  managerwindow

Available object types

-

Depends on objects created in the system.

Only those object types are available for selection for which the value "INFORMATION" or "ALARM" is selected on the Events tab in the Processing messages column in the ddi.exe utility (see The Events tab).

6

Number drop-down list

Select from the list

Sets the number of the object by which the events should be displayed in the Incident handler managerwindow

Positive integers

-

Depends on the number of objects of the specified type created in the system

7

Name drop-down list

Automatically

Sets the name of the object by which the events in the Incident handlermanager window should be displayed

Names of objects created in the system

-

Depends on objects created in the system.

8

Event type drop-down list

Select from the list

Sets the events displayed in the Incident handler managerinterface window

Events available to the selected object

-

Depends on the object type

9Logic fieldType-in the value in the fieldSpecifies the logic that will be used to handle the events of the corresponding object. The logic has to be specified. Otherwise, the selected events will not be displayed. Logic name-

A string containing a sequence of any characters (letters, numbers, service characters except for > and <), case-insensitive.

Number of characters - from 1 to 255

10Priority drop-down listSelect from the listPriority level for events of the corresponding objectPriority level-Depends on the priority templates created on the Main tab
11Timer(sec) fieldType-in the value in the fieldSpecifies the time in seconds from the moment the event occurred, after which the TIME_IS_OVER event is generated. The timer will also count down the specified time in the interface in the Time(sec) column until it reaches zero.Time in seconds->=0

12

Auto-escalation(s) field

Type-in the value in the field

Sets the time in seconds from the moment the event occurs, after which the event will be automatically escalated. Auto-escalation is performed within one Incident handlermanager and works if the operator has the escalation rights

Time in seconds

-

>=0

...

ParameterParameter value setting methodParameter descriptionRepresentationDefault valueRange of values
Priority localization template window
1Priority levelType-in the value in the fieldPriority levelPriority number-Numeric value, positive integer
2Value fieldType-in the value in the field

Priority description. If the priority description is set, then it will be displayed in the Incident handlermanager, otherwise the priority level will be displayed.

Priority description-

A string containing a sequence of any characters (letters, numbers, service characters except for > and <), case-insensitive.

Number of characters - from 1 to 255

Columns settings window
3Number of columns fieldType-in the value in the field

Sets the number of columns when displaying the event processing logic in the Incident handler manager interface

Positive integers40-100
4Column width fieldsType-in the value in the field

The width of the columns in the event handling interface in pixels or as a percentage of the entire width of the Incident handlermanager interface.

Pixels or fractions150 pixelsPercentage values ​​should be set in fractions of 1, for example, 0.25. If a value greater than 1 is specified, then it will be taken in pixels.

...