To remove the Axxon PSIM software from the Start menu do the following:

  1.  In the command prompt Windows start menu select the following: Start -> Programs -> Axxon PSIM folder and then Uninstall in the drop down list, as shown in the figure Remove in it.
    Image Modified
    As a result the Select Action dialog box is displayed.
  2. Set the switch to Remove.
  3. If Axxon PSIM settings are to be saved in the database, set the Save program settings and configuration files (recommended) checkbox.

    Info
    titleNote.
    If the “sync.xml” file was changed, then after removing with saving of the configuration it will not be deleted, but the next time you install Axxon PSIM it will be overwritten.
    If you made changes to ddi or dbi files installed along with Axxon PSIM software, then these files will be deleted when removing Axxon PSIM even with Save program settings and configuration files (recommended) checkbox set. If the user has created new ddi or dbi files, they will be saved regardless of the checkbox.


  4. Click the Next button.

    Info
    titleNote.
    Click the Cancel button to interrupt Axxon PSIM software removing.


    The dialog window displaying the removing of Axxon PSIM software will be displayed.

    After removing the files, message, informing about the removing of Axxon PSIM software will be displayed.

  5. Click the Finish button.
Info
titleNote.

For complete deletion of Axxon PSIM software files delete the installation catalog and all the created Video folders for storing the audio and video recordings manually.
Image Modified


Info
titleNote.
Please take into consideration, that the name of the Axxon PSIM software installation folder may differ from the default name (C:\Axxon PSIM).

...