The LPR channel can operate together with the main motion detector of the Axxon PSIM platform. This helps decrease the CPU load.

Info
titleNote.

This setting is given only when AUTO-Uragan, CARMEN-Auto, ARH-Containers, VIT, or LPR IntelliVision program module is used.

If the LPR channel works in conjunction with the Axxon PSIM main motion detector, it scans the video image for LP numbers when the motion detector is in an alarmed state, i.e. some motion is detected in the camera viewing zone.

Info
titleNote.

When the main motion detector is not alarmed, the LPR channel does not scan the video image to find and recognize the LP numbers.

If the joint operation is disabled, the LRP channel scans each incoming frame.

To enable joint operation of the LPR channel and the Axxon PSIM motion detector, do the following:

  1. Go to the LPR channel object settings panel, corresponding to the activated module (see Activating the software module used for identifying the plates section).

  2. Check the Enable on motion detection trigger checkbox (1).
  3. Click Apply (2).