Go to documentation repository
Configure the Face detectionDetection module operation with a thermal camera or an external system as follows:
From the Combined work drop-down list (1) select the combined operation mode:
No - combined combined operation mode is not used.;
Combine with thermal camera temperature - receiving the temperature and coordinates of a captured face frame from the thermal camera. A photograph of a captured face will be obtained from the capturing camera. If this mode is selected, the following setting become available:
Thermal camera reply timeout, s (2) - − sets the timeout in seconds for receiving data from the thermal camera.;
Info | ||
---|---|---|
| ||
The FIND_PERSON event will be generated only when the temperature is received from the thermal camera or after the time specified in the Thermal camera reply timeout, s parameter. |
Get photo from thermal camera - − receiving the temperature and photos temperature and photos of a captured face from the thermal camera.;
Get photo and metadata from external system - − receiving the temperature and photos of a captured face from a thermal camera or Axxon One.
Click Apply (3) to save the changes.