Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Info
titleNote.

It is not recommended to create more than 4 Train detection objects for correct operation of the Train detection module.

The Train detection module can be configured on the settings panel of the Train detection object created on the basis of the Camera object on the Hardware tab of the System settings dialog window.

The Train detection module is configured as follows:

  1. Go to the Train detection control panel.
  2. Click the Settings button. The Detection settings windows will open.
  3. Specify the surveillance area on the video image:
    1. Click the Stop video button to capture the video image (1).
    2. Click the Surveillance territory button (2).
    3. On the captured video image (3) sequentially specify nodal points of area to be analyzed by clicking the left mouse button (1). It is possible to add only one area. While attempting to add the second area the first one will be deleted. After area specifying the remaining part of video image will be darkened.

      Info
      titleNote.

      To remove the area click the  button next to the Surveillance territory button.


      Info
      titleNote.

      The surveillance territory is to be specified in such a way as to be no any motion in it except of the train motion.


      Note
      titleAttention!

      Setting the Surveillance territory is a mandatory requirement for the detection module operation.


  4. Go to the Setting tab (4) and do the following:
     
    1. In the Number of processed frames per second (0.016-100) field (5), set the number of frames per second that will be processed by the detection tool.
    2. Click the OK button to save changes and return to the control panel of the Train detection (6).

      Info
      titleNote.

      To return to the control panel of the Train detection without saving changes, click Cancel.


  5. Click Apply on the Train detection control panel.