To shut down an the Axxon Next Server, complete one of the following actions:

  1. Select from the menu Start -> All Programs -> Axxon Next  -> Shut down Server or in the Axxon Next Tray Tool utility (see Axxon Next Tray Tool).

    Info
    titleNote

    Run the command with the administrator permissions.


  2. Stop the NGP Host Service.

By default, the Axxon Next Server shutdown time is set to 60,000 ms. If the Server does not shut down within the set time, the second forced attempt will be made to shut down the Server.

You can use the NGP_SERVICE_STOP_TIMEOUT_MS system variable (see Appendix 10. Creating system variable) to increase the Server shutdown time. The value of the variable should be specified in milliseconds.