Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Go to the settings panel of the Satel Panel object.
  2. Click the Send accounts button (1) to send the data of the Access Manager module to the Satel INTEGRA panel.
  3. Set the Send users dynamically checkbox (2) to automatically transfer the data of the Access Manager module to the Satel INTEGRA panel if they change.
  4. In the PIN code to control panel you may set the PIN code used to authorize the connection to the control panel (3).
  5. Set the Use user PIN code for reactions checkbox to make the panel operators (ACFA Intellect Axxon PSIM users) to enter their own PIN codes to react to events from the panel in addition to the main panel code (4). The user PIN code is set in the Intellect Axxon PSIM user settings, see User registration and removal.
  6. In the Time to second PIN enter field you may select the delay between entering the panel code and the user code in seconds (5).
  7. Configure the additional emulations that facilitate the panel operation using the Map (see Working with the Satel INTEGRA Integration Module):
    • If the Show communication lost at all objects checkbox is set, the panel communication failures will be indicated on all device object icons on the Map (1).
    • If the Show alarms from zones at the panel icon checkbox is set, the alarms from Satel INTEGRA zones will be indicated on the Satel Panel object icon on the Map (2).
    • If the Show armed zone at the inputs checkbox is set, the armed zone will be indicated on the Satel INTEGRA output icons on the Map (3).
  8. Click Apply (9) to save the changes.

...