Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

To add event parameters to ddi-file use the System configuration ddi.exe utility. Working with this utility is described in the Intellect Axxon PSIM software package. Administrator's Guide, latest version of which is available in AxxonSoft documentation repository.

...

  1. Shutdown the ACFA PSIM software package.
  2. Open the .ddi file corresponding to the required integration module of the ACFA PSIM software using the ddi.exe utility.

    Info
    titleNote.

    Ddi files are located in the <Intellect Axxon PSIM software installation directory>\Languages\en folder.

  3. Select the required object on the Names tab.
  4. Go to the Events tab (1) and select the required event (2).
  5. In the Parameter field enter the parameter name displaying in the Debug window (3) – see Event parameters in the Debug window section.
  6. In the Name field enter the name of parameter in natural language form (4).
  7. From the Type drop-down list select the parameter type: EDIT (text) или COMBOBOX (set of values) (5). If the COMBOCOX type is selected, specify available parameter values in the Element and Value columns.
  8. Save changes in the .ddi file.
  9. Start the ACFA PSIM software package.

...

Note
titleAttention!

Changed ddi-files will be overwritten when updating the ACFA PSIM software. So create backup copies of changed ddi-files before updating the ACFA PSIM software and place them to the <Intellect Axxon PSIM software installation directory>\Languages\En folder after updating.

...