Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Go to the setting panel of the SALTO Server object.
  2. In the Server IP-address field set the IP address of computer on which SALTO ACS software is installed (1).
  3. In the Server port field set the TCP/IP port address of SALTO integration module connection to SALTO ACS software which is designed for transferring data by SHIP-protocol while configuring the vendor software (2).
  4. In the Listening port field set the port to which the queries of  SALTO ACS software will be forwarded (3).
  5. In the Number of read events field enter the number of events read from the SALTO ACS software for one system query (4). 
  6. Set Use external ID for TAM checkbox to use external user ID while searching users for getting information about passes (5). If checkbox is not set the user ID in the Intellect Axxon PSIM software package will be in use.
  7. Set Trace changes in ACS checkbox for automatic forwarding of user changes, time schedules and access levels to SALTO ACS software (6).
  8. From the Default encoder drop-down list select the encoder which will be used on default (7).
  9. To save changes click Apply (8).

...