Go to documentation repository
For the Traffic violations detection module operation program module for identifying the plates and that is being set up is required (see Activating the program module, used for identifying the plates section).
Note | ||
---|---|---|
| ||
For correct operation of the Traffic violations detection module configure the synchronous video camera from which frames and video fragments will be saved (detailed information about configuring the synchronous video camera is presented in the Selecting the video cameras to work with the LPR channel page). |
To set the Traffic violations detection module, do the following:
In Traffic lights signal dropdown list select the object (Sensor or Traffic Light Detection) by signal of which the light of traffic light is detected (1).
Info | ||
---|---|---|
| ||
Information about Sensor object is presented in the Creating and configuring the Sensor system object section. Information about Traffic Light Detection module is presented in Detector PackDetectorPack PSIM. User Guide User’s Manual document (see Detector PackDetectorPack PSIM). |
Note | ||
---|---|---|
| ||
For correct operation of the Traffic violations detection module disarm the corresponding Sensor object. |
Set up the displaying of violation areas:6.1
Click Setting violation areas (5). The window of the same name opens.
Click Stop video to set the violation areas. As the result the frame on which it's necessary to set the violation areas, is displayed.
Set the areas corresponding to following zones: before stop line. stop line, crosswalk, crossroads. To set the violation areas, click the points corresponding to the boarder of selected area in the video frame.
Click OK.
Info | ||
---|---|---|
| ||
To remove the area click the button close to the corresponding button. |
In the Time of stop for recording field enter time (in milliseconds) that determines the time interval during which the vehicle should stay still while registering the Stop over crosswalk line violation (7).
Info | ||
---|---|---|
| ||
If the Stop over crosswalk line violation is registered incorrectly, you can change the values of the registry key parameters that affect its accuracy. Changing the registry key parameters values enables the alarm activation even if only one plate is recognized at the crosswalk, regardless of the vehicle movement. To do this, change the Alarms.CrossWalkOne and Alarms.LimitedByBestResult values to 1 (for details, see Registry keys reference guide and Working with Windows OS registry). |
In the Interval field enter time (in milliseconds) that determines the time interval between saving additional photos (9).
Note | ||
---|---|---|
| ||
For correct operation of synchronized frames recording set the checkbox in Automatic recording on LPR channel object setting panel and set value of time that is bigger than the product of Number of frames for saving and Interval of frame saving parameter points. |
Click OK. The specified parameters will be added to the Additional recognizer table.
Info | ||
---|---|---|
| ||
To modify recognizers in the rable, right-click the required recognizer to open the functional menu. Click Delete all button if the Additional recognizers table it to be cleared. |
To save the changings click Apply.
Info | ||
---|---|---|
| ||
The recognition results can be saved to the hard drive for the Traffic violations detection module debugging. To do this, change the SaveRecognitionResult registry key parameter value to 1 (for details, see Registry keys reference guide and Working with Windows OS registry). |
The Traffic violations detection module setup is complete.
Logic of working the Traffic violation detection is explained in the following example.
...
Several cameras are used for this purpose:
...