  1. Specify the position and size of the Captions search window (1): X is the indent relative to the left border of the video image, Y is the indent relative to the top border of the video image, W is the window width, H is the window height. 

    The coordinates can be set up using the visual method. Click the Image Removed Image Added button and use the mouse to set the location and size of the sample window, then click OK. The coordinates of the sample window will be filled in the X, Y, W and H fields automatically.
    Image Modified

    Image Modified

  2. In the Monitor drop-down list, select the number of the computer monitor to display the Captions search window (2).
  3. By default, the option of moving the Caption search window by dragging with left mouse button is enabled. To disable it, uncheck the Allow moving checkbox (3).
  4. Set the overlay type by checking the Overlay (Type I) or Overlay (Type II) checkbox (4).

    Info
    titleNote.

    In most cases, the optimal mode of processing the video is DirectDraw — Overlay (Type II). If it is necessary to display the video from Fisheye cameras or the signal decoded using Intel QuickSync technology, select the Overlay (Type I)Direct3D. Also, the Overlay can be disabled completely.


  5. To allow the operator to print the search results, check the Print reports checkbox (5).

  6. If archive video is to be displayed in the Captions search window in the 16:9 format, then set the Maintain aspect ratio 16:9 (6) checkbox checked. If the checkbox is set unchecked, then 4:3 aspect ratio is set even for HD video.

  7. Click Apply (7).

The Captions search window is now set. 


Info
titleNote.

To clear the history of user queries in the Captions search window, click the Clear history button.