Go to documentation repository
...
To limit operator access to the administration of certain objects of Axxon PSIM program software , do the following:
Open the required User permissions object in the objects tree under the User permissions button (2).
The settings panel for this object opens on the right side of the System Settings window.
The tree in the lower part of the settings panel represent the rights of the current operator. Checkboxes to the left of the objects indicate and allow changing the administrative, control or viewing rights for these objects. The components of the tree represent the system objects which the current user can administer according to their rights’ settings. Name of marks corresponds to object names, which administration, control and monitoring may be accessible to Operator with proper rights (3).
Correspondence of mark type to Operator rights is given in the table.
Type of mark | Right to administer | Right to control the object | Right to monitor the object |
A gray mark | Yes | Yes | Yes |
A green mark | No | Yes | Yes |
An M mark | No | No | Yes |
A cross mark x | No | No | No |
Info | ||
---|---|---|
| ||
The administrative, control or viewing rights to interface objects depend on the rights to the Computer objects. The rights to the Computer object have a higher priority. For example, if the user rights allow the administration of the Display object, but prohibit the administration of the Computer object to which this Display is assigned, then a user logged on to the computer prohibited for administration will not be able to administer the Display object (see also Assigning the displays to the operator workstations). |
3. After After finishing the setting, click the Apply button(4).
The following hotkeys can be used for objects tree control:
...