Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Create the Telemetry controller object.
    1. Configure the Telemetry controller object as follows:
      Image Modified
    2. Specify the Samsung communication protocol (1).

    3. In the Port list list, select the number of the serial (COM) port for connecting to the telemetry controller (2).
    4. Specify 9600 value for the Speed parameter.Rate parameter (3). 
    5. Specify None value for the Parity parameter parameter (4).
    6.  Set the DTR and RTS checkboxes checked (5,6).
  2. Create the Control panel object under the Telemetry controller object.
  3. Configure the Control panel object as described in Telemetry control panel configuration section.

Samsung SSC-2000 telemetry control panel is now configured in Axxon PSIM.