Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

ParameterExecuted function
Mode

The following modes are available for the Forteza sensors:

  • Duty mode - displays the interference level
  • Adjustment - displays the signal level

The following modes are available for the MIR sensors:

  • Duty mode - displays the interference level
  • IR adjustment - displays the signal level of the infrared channels

  • RB adjustment - displays the signal level of the radio ray (radio beam) channels

Intrusion delay
  • Low 0,1 - 1 m/s
  • Low 0,1 - 4 m/s
  • Low 0,1 - 10 m/s
Sensitivity

10% to 100%


Note
titleAttention!

Adjusting for sensors should be performed in accordance with the manufacturer's technical documentation.

...

Info
titleNote

After the adjustment is made, the sensors should be switched to the duty mode and the Period of indicator updating parameter value should be set to Do not use. These actions will improve the general responsiveness of the system (see Configuring Forteza two-position sensor).


Info
titleNote

For the Format sensors, an alarm is generated only when it occurs simultaneously on the IR and RB channels.

...