The Face recognition report refers to is a part of the Face characteristics recognition channel module and Face Recognition Server. It is necessary to create and configure the corresponding objects in Intellect (see Face Intellect configuration and setup procedure). |
To build generate the report, select the Face recognition report from the list of Access Manager reports (see Selecting a type of reports by Visitors counting detectors) from the list of Access Manager reports and specify the report parameters in the displayed dialog boxopened form.
- From the Face Recognition Server drop-down list (1), select the Face Recognition Server object, the information from which should be displayed in the report.
From the Face types drop-down list (2), select the face types the information on which should be displayed in the report:
All faces;
Only unrecognized;
Only recognized.
- In the Select the columns for the report field (3), check set the boxes checkboxes next to the columns that should be displayed in the report. You can also change the order of the columns: to do this, use the left mouse button to move the column name up or down. You can select up to 5 columns.
- If necessary, in area (4), set a filter by face characteristics and temperature, selecting only those face characteristics that should be displayed in the report.
- In the Departments/users field (5), select the departments or users, information on which should be displayed in the report. If necessary, you can use the search for a user by their first/last name. To do this, enter user’s first/last name in the search field (6) and click the Search button (7). To clear the results, click the SearchClearTree button (8). Selecting the department is not available when selecting Only only unrecognized Face face type (see item 2).
In the Period fields (9) select the time period for which you want to build generate the report.
Info title Note - If the Custom 2 period period is selected, enter the date of start and end periods for which the report is to should be created in the the from and to fields using the Calendar tool. Click the button near the corresponding field to use the Calendar tool. Enter the start and end time of the period using the button.
- The Custom 3 period allows you to set the time interval from Yesterday (time) to Today (time) relative to the report date.
- Click the Execute button (10). As a result, the report with the specified parameters is displayedgenerated.
Example of the Face a face recognition report:
All possible fields of the report are described in the table.Field name Description Photo Photo from the camera Reference photo Employee's photo from the Face Intellect database Full Name Employee's full name First name Employee's first name Last name Employee last name's last name PatronymicPatronym Employee's patronymic name LP number Employee's vehicle license plate number Vehicle Employee's vehicle modelbrand Card number Employee's access card number Card code Employee's access card code Card issue date Employee's access card issue date Access levels Employee's access level Phone Employee's phone number Company/Department Company/Department where the employee works Department Department to which the employee belongs Comment Commentary Card expiration date Employee's access card expiration date Card pin code Employee's access card pin code Gender Employee's gender Emotion
Employee's emotion
Glasses
Glasses on face
Facial hair
Facial hair
Hair color
Hair color
Type of bald head
Type of bald head
Headwear
Headwear
Artificial face
Artificial face
Face concealment Face concealment Temperature Employee's face temperature in degrees Celsius Building the The face recognition report is completegenerated.
Info | ||
---|---|---|
| ||
The maximum number of faces in the report is 1000. The data on other faces will not be displayed in the Face face recognition report. |