Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

For the precise tracking of moving objectsthe object under observation, you must calibrate PTZ cameras by mapping at least six PTZ positions to points in the field of view of each panoramic camera.

The more positions you map, the more precisely the PTZ camera is able to follow moving objects. It is recommended to map eight or more points.

...

should calibrate the telemetry device by matching at least four telemetry device positions with the frame points of each overview camera.

Note
titleAttention!

The recommended number of points that should be set is 4-10. If you add more points, the algorithm will be configured more accurately. However, this will increase the chance of introducing a wrongly set point into the calibration algorithm, which can lead to an overall deterioration of the operation quality.

The points set in the calibration setting should not be on the same line for both the overview and the PTZ camera. It is recommended to set the points for both cameras so that they evenly cover the entire frame.

The calibration points should be set on the same surface (floor, ground). It is not recommended to set the points on different surfaces (for example, when some points are on the ground, and other points are on a tree, etc.).

To calibrate the telemetry device, do the following:

  1. Select the overview camera from the list (see Linking panoramic cameras to a PTZ camera).
  2. Focus the PTZ camera on any point.

...

  1. To do this, in the preview window click the button and change the

...

  1. orientation of the lens in one of the following ways:
    1. Left-click on the frame and

...

    1. holding the

...

    1. button,

...

    1. move the

...

    1. mouse cursor in the

...

    1. required direction.
    2.  Use the Point&Click function (see Control using Point&Click).
  1. Left-click to add a point

...

  1. to the frame of the

...

  1. overview camera

...

  1. to which the PTZ camera is currently oriented.

Image Modified

...

titleAttention!

...

Note
titleAttention!

The

...

object under observation should be inside the

...

frame of

...

the PTZ camera.

4. Repeat

...

the process

...

to set at least

...

4 points.
5. Repeat the process for all

...

overview cameras (

...

select

...

the camera by clicking in the list of the overview cameras).

...

6. Click the Apply button to save the calibration points

...

.

Calibration of the telemetry device is complete.

It is recommended to After setup is complete, we recommend that you perform a calibration check after calibration is complete. To do this, do the following:

  1. Click the button to the right of the preview for that PTZ window of the overview camera.
  2. Click on different points in the

    camera's field of view

    image of the overview camera. If the PTZ camera is positioned correctly,

    it needs no

    the calibration is correct.

Info
titleNote

To delete the calibration points, click the button.

...