Go to documentation repository
Page History
...
№ | Parameter | Method for setting the parameter | Parameter description | Symbols used | Default value | Value range |
1 | Identification number* | Automatically | Displays the identification number of the Event viewer object in the digital distributed video surveillance system. | Sequence of numbers | - | From 1 and above. Depends on the number of Event Viewer objects in the digital distributed video surveillance system. |
2 | Name* | Type-in the value in the field | Sets the name of the Event viewer object in the digital distributed video surveillance system. | Latin, Cyrillic and service characters | Event Viewer | A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive Number of symbols – from 1 to 60. |
3 | Disable | Checkbox | Sets the status of the Event viewer object (enabled or disabled) in the digital distributed video surveillance system. | Boolean type | No | Yes – the Event viewer is disabled and is not in use. No – the Event viewer is enabled and is in use. |
4 | Screen | Select in the list | Specifies the parent Display object of the digital distributed video surveillance system, to which the given Event viewer object refers. | Names of Display object s registered in the system | Name of the parent Display object . | Depends on the number of Display object s in the digital distributed video surveillance system. |
The Settings group | ||||||
5 | X | Type-in the value in the field | Sets the coordinate in the X horizontal axis for the upper left corner of the window of the Event viewer interface object on the screen. | % of the screen width | Not set | From 0 to M*100, where M is the number of monitors installed. |
Y | Type-in the value in the field | Sets the coordinate in the Y vertical axis for the upper left corner of the window of the Event viewer interface object on the screen. | % of the screen height | Not set | From 0 to M*100, where M is the number of monitors installed. | |
6 | W | Type-in the value in the field | Sets the window width of the Event viewer interface object. | % of the screen width | Not set | From 0 to M*100, where M is the number of monitors installed. |
H | Type-in the value in the field | Sets the window height of the Event viewer interface object. | % of the screen width | Not set | From 0 to M*100, where M is the number of monitors installed. | |
7 | Monitor | Is selected in the list | The number of monitor in OS for which coordinates are specifying | Numbers of monitors | 1 | 1-16 |
8 | X | Click the button | Open the window to set Event viewer window size and position using mouse | - | - | - |
9 | Allow moving | Checkbox | Allows the operator changing the position of the Event Viewer by clicking on it. | Boolean type | No | Yes – Operator can change the position of Event viewer. No – Operator cannot change the position of Event viewer. |
10 | Over all windows | Checkbox | Allows to display the Event viewer box on top of all windows | Boolean type | No | Yes - The Event viewer window is displayed on top of all windows. No - The Event viewer window is displayed in standard mode. |
11 | Show video | Checkbox | Allows Operator viewing archive footage of the events, initiated by the Event Viewer as Record to disk using the Event viewer box. | Boolean type | No | Yes – Operator is allowed viewing the archive footage using the Event Viewer window. No – Operator is not allowed viewing the archive footage using the Event viewer window. |
12 | Show object on map | Checkbox | Allows Operator viewing objects, displayed in the Event viewer window, on the map. | Boolean type | No | Yes - Operator is allowed viewing the objects, displayed in the Event Viewer window, on the map. No - Operator is not allowed viewing the objects, displayed in the Event Viewer window, on the map. |
13 | Show report | Checkbox | Allows Operator creating a printed form of the report and printing out the information about all events registered by the Event viewer within the pre-set period of time. | Boolean type | No | Yes - Operator is allowed creating a printed form of the report and printing out the information about all events registered by the Event Viewer within the pre-set period of time. No - Operator is not allowed creating a printed form of the report and printing out the information about all events registered by the Event Viewer within the pre-set period of time. |
14 | Load protocol | Checkbox | Defines, whether or not the latest 1000 events registered by the Event viewer with the latest system start, should be downloaded with the launch of Intellect™ software. | Boolean type | No | Yes - the latest 1000 events registered by the Event viewer with the latest system start, should be downloaded with the launch of Intellect™ software. No - the latest 1000 events registered by the Event viewer with the latest system start, should not be downloaded with the launch of Intellect™ software. |
15 | Hide Region | Set the checkbox | Hides the Region column in the Event viewer. | Boolean type | No | Yes – the Region column is not displayed No – the Region column is displayed |
16 | Hide Card | Set the checkbox | Hides the Card column in the Event viewer. See Card number displaying in the Event viewer window for access events section in Access Manager Module Settings and Operation Guide. | Boolean type | No | Yes – the Card column is not displayed No – the Card column is displayed |
17 | Keep colored after blinking | Checkbox | Allows highlighting the alarm messages by the selected color after the blinking stops. | Boolean type | No | Yes - the alarm messages continue to be highlighted by the selected color after the blinking stops. No - when the alarm message has finished blinking, it is no longer highlighted by selected color; it becomes highlighted by the color specified in the filter. |
The Advanced settings group | ||||||
18 | View days | Type-in the value in the field | Specifies the period over which events are to be displayed in the Event Viewer, if there are more than 10,000 events (or other value set by Max.number of rows). If there are less events, then all events are displayed regardless of the value of this parameter. | Days | 1 | More than 1 |
19 | View events | Select in the list | Sets the events for displaying in the window of the Event Viewer. | - | All events | All events – all events are displayed in the Event Viewer window Last event – one last event is displayed in the Event Viewer window All last events – all last events are displayed for all selected objects |
20 | Max.number of rows | Type-in the value in the field | Sets the maximum number of events to display in the Event viewer | Non-negative integer | 10000 | 1 – 50000 |
21 | Background color | Select in the list or on the Select color panel. | Sets the background color in the Event Viewer box | RGB, CMY or HSL. | White | Corresponds to the standard range of the selected color system. |
22 | Text color | Select in the list or on the Select color panel. | Sets the text color in the Event Viewer box | RGB, CMY or HSL. | Black | Corresponds to the standard range of the selected color system. |
23 | Color of alarm messages | Select in the list or on the Select color panel. | Sets the color of the alarm message rows in the Event viewer window. Duration of blinking, sec is to be other than 0. | RGB, CMY or HSL. | Red | Corresponds to the standard range of the selected color system. |
24 | Color of info messages | Select in the list or on the Select color panel. | Sets the color of the information message rows in the Event viewer window. Duration of blinking, sec is to be other than 0. | RGB, CMY or HSL. | Blue | Corresponds to the standard range of the selected color system. |
25 | Duration of blinking, sec | Type-in the value in the field | Sets the duration of alarm message blinking in the Event viewer window. | seconds | Not set | More than 0 |
26 | Font:<current font> | Click the button | Sets the font of information messages in the Event viewer window | Standard Font Windows dialog box | Depends on OS settings | - |
...