Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1Country drop-down listSelect value from the listFor AUTO-Uragan, VIT, RoadAR, LPR IntelliVision software modules
Selection of the country which numbers it is necessary to recognizeList of available national license plate templatesDepending on the recognition moduleDepending on the number of available national license plate templates
Module drop-down listSelect value from the listFor CARMEN-Auto, ARH-Carriages, ARH-Containers software modules
Selection of the license plate recognition SDKList of license plate recognition SDKDepending on the recognition moduleDepending on the number of installed license plate recognition SDK

2







Select cameras group

License plates recognition drop-down list

Select value from the list

Main video camera for license plate recognition

List of available Camera objects

Camera 1

Depending on the number of available Camera objects

Synchronous recording drop-down list

Select value from the list

Additional video camera operating together with the main camera

List of available Camera objects

None

Depending on the number of available Camera objects

Auto recording checkbox

Set the checkbox

Enabling the automatic recording on the LP number recognition

Boolean

No

Yes – automatic recording enabled,

No – automatic recording disabled

Auto recording, s field

Enter the value in the text field

Setting the auto recording duration (in seconds)

Seconds

10

0 - 100086400

Enable on motion detection trigger checkboxSet the checkboxStarting auto recording on receiving an event from the motion detectorBooleanNo

For normal mode:

Yes –  if the camera is armed, the LPR channel scans all video images until the basic motion detection of the Intellect software is in the Alarm mode; If the camera is not armed, the LPR doesn't work, but manual start using scripts is available (see item 6 in the Scripts used in the Auto-Intellect software package section). Recognition will process frames until the stop command will be done.

No – the LPR channel scans video images permanently.

For Parking mode:

Yes –if the camera is armed, the LPR channel scans all video images, until the plate will be recognized, after it recognition stops even if the Alarm mode is still in process and procedure repeats when the new trigger of alarm is activated; if the camera is not armed, the LPR doesn't work, but manual start using scripts is available (see item 6 in the Scripts used in the Auto-Intellect software package section). Recognition will process frames until the plate will be recognized and then will stop before new manual start.

No – the LPR channel scans video images permanently

Reduce large resolution checkboxSet the checkboxFrame handling setupBooleanYesYes – the lesser frame is stretched, the bigger one is cut off
No– the lesser frame is stretched, the bigger one is handled without changes

3

Settings button 

Not available for: 

  • Remote recognition
  • ARH-Carriages
  • ARH-Containers
  • CARMEN-Auto
  • IntLab

Click the button

Access to frame sign settings

-

-

-

4Entry checkboxSet the checkbox

The vehicle's movement direction will be treated as Entry to the territory

BooleanNo

Yes - The LPR channel considers the vehicle's movement direction as Entry to the territory.

No - The LPR channel does not consider the vehicle's movement direction as Entry to the territory.

Note. This setting is taken into account in the Intellect Web Report System when working with Auto reports (see Intellect Web Report System. User Guide).

The Recognition settings tab

...