Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. In the Entry dropdown list select the Region object corresponding to the area on the side of exit from the access point (4).
  2. In the Exit dropdown list select the Region object corresponding to the area on the side of entrance to the access point (5).
  3. Set parameters of access control at entrance (6):
    1. In the Entry dropdown list select the one that will decide whether to give access or not and whether to register it or not – Intellect Server or operator;

      Info
      titleNote.

      To process the request operator is to create a Photo ID interface Event manager interface object and configure it for the Operator's query (Access granted) event. For more information about this object and its functions, please refer to Photo ID User Event Manager Module Settings and Operation Guide.


    2. If it is considered that passing is performed just after placing the access card to the reader, then check the Don't wait access cycle for exit checkbox. If the passing is considered to be performed only after passing the access point (i.e. door sensor is triggered), uncheck this checkbox.
  4. Set parameters of access control at exit (7). The parameters are the same as those of access control at entrance (see the previous item).
  5. Click the Apply button to save all changes.
  6. Repeat steps 1-9 for all required Castle ACS access points.

...