Go to documentation repository
Page History
...
If descending = false, then the events in the response will be sorted by time in ascending order. If descending = true, then the events will be sorted in descending order.
limit - the limit of events in the response.
...
- type − type of event; the actual types of events are given in the AxxonSoft\bl\events.proto file;
- subjects − subject of event (server, device, archive, detector, etc.);
- values − exact value of event;
- texts − brief description of event.
Get events about status change of a specific camera
Code Block |
---|
{ "method": "AxxonSoft.bl.events.EventHistoryService.ReadEvents", "data": { "range": { "begin_time": "20200225T152806.572", "end_time": "20200225T153806.572" }, "filters": { "filters": [ { "type": "ET_IpDeviceStateChangedEvent", "subjects": "hosts/Server1/DeviceIpint.10" } ] }, "limit": 300, "offset": 0, "descending": false } } |
Get events about disconnection of all cameras
Code Block |
---|
{ "method": "AxxonSoft.bl.events.EventHistoryService.ReadEvents", "data": { "range": { "begin_time": "20200226T074425.274", "end_time": "20200226T075425.274" }, "filters": { "filters": [ { "type": "ET_IpDeviceStateChangedEvent", "values": "IPDS_DISCONNECTED" } ] }, "limit": 300, "offset": 0, "descending": false } } |
Get
...
events from all domain LPR detection tools
Code Block |
---|
{ "method": "axxonsoft.bl.events.EventHistoryService.ReadEvents", "data": { "range": { "begin_time": "20211020T120000.000", "end_time": "20211020T200000.000" }, "filters": { "filters": [ { "type": "ET_DetectorEvent", "values": "DG_LPR_DETECTOR" } ] }, "limit": 10000, "descending": true } } |
...
The subject and the text of event are specified in filter.
Search by a specific camera for all events that contain the word tracker (2 events limit)
Code Block |
---|
{ "method": "AxxonSoft.bl.events.EventHistoryService.ReadTextEvents", "data": { "range": { "begin_time": "20200226T082741.159", "end_time": "20200226T083741.160" }, "filters": { "filters": [ { "subjects": "hosts/Server1/DeviceIpint.7/SourceEndpoint.video:0:0", "texts": "tracker" } ] }, "limit": 2, "offset": 0, "descending": false } } |
...
Info | ||
---|---|---|
| ||
If an operator’s comment was specified for the alarm, it will be in the response with the frame coordinates. |
Get alerts by filter
...
Alarms start time on a specific camera
Code Block |
---|
{ "method": "AxxonSoft.bl.events.EventHistoryService.ReadAlerts", "data": { "range": { "begin_time": "20200225T150845.757", "end_time": "20200225T151845.758" }, "filters": { "filters": [ { "subjects": "hosts/Server1/DeviceIpint.7/SourceEndpoint.video:0:0", "values": "BEGAN" } ] }, "limit":100, "offset":0, "descending": false } } |
Search for LPR events
Search for a specific LP number
Code Block |
---|
{ "method": "AxxonSoft.bl.events.EventHistoryService.ReadLprEvents", "data": { "range": { "begin_time": "20200226T104305.137", "end_time": "20200226T105305.137" }, "filters": { "filters": [ { "subjects": "hosts/Server1/DeviceIpint.1/SourceEndpoint.video:0:0", "values":"Н829М7" } ] }, "limit":50, "offset":0, "descending": false } } |
Search by part of a LP number
Code Block |
---|
{ "method": "AxxonSoft.bl.events.EventHistoryService.ReadLprEvents", "data": { "range": { "begin_time": "20200226T104305.137", "end_time": "20200226T105305.137" }, "filters": { "filters": [ { "subjects": "hosts/Server1/DeviceIpint.1/SourceEndpoint.video:0:0" } ] }, "limit":50, "offset":0, "search_predicate":"*82*", "descending": false } } |
Subscription to
...
events
If you subscribe, you will be notified as events occur.
Subscription to
...
LPR detection tool events
Code Block |
---|
{ "method": "axxonsoft.bl.events.DomainNotifier.PullEvents", "data": { "subscription_id": "a000ed13-3b8f-4cef-a450-0199dc259w37", "filters": { "include": [{ "event_type":"ET_DetectorEvent", "subject":"hosts/Server1/AVDetector.1/EventSupplier" }, { "event_type":"ET_DetectorEvent", "subject":"hosts/Server1/AVDetector.2/EventSupplier" }, { "event_type":"ET_DetectorEvent", "subject":"hosts/Server2/AVDetector.1/EventSupplier" } ] } } } |
where
- subscription_id − subscription ID (set arbitrarily in UUID format; mandatory parameter).
- event_type - event type (optional parameter).
- subject - subject of the event (detectors in this example; optional parameter).
To
...
receive events using a subscription,
...
do the following:
- Run a request with the PullEvents method.
After receiving the "200 OK" response, the events will be accumulated. - After the required time interval, run a request with the DisconnectEventChannel method.
You will receive a list of events that occurred between the two requests.
The request body with the DisconnectEventChannel method:
Code Block |
---|
{ "method": "axxonsoft.bl.events.DomainNotifier.DisconnectEventChannel", "data": { "subscription_id": "a003ed13-3b8f-4cef-a450-0199dc259w37" } } |
...
Info | ||
---|---|---|
| ||
The value of the subscription_id field should not be different equal in the all requests. |