To verify the current configuration of objects in Axxon PSIMsoftware and restore it from the template, do the following:
Download the template for which the object configuration is to be verified inAxxon PSIMsoftware (see the Downloading and editing the template section).
Go to the Configuration menu on the control panel and click the VerifyTestbutton. As a result the objects which current configuration in Axxon PSIMsoftware differs from that one in the template will be marked red in the objects tree.
To view object parameters in the template which values are different from those ones in the Axxon PSIMsoftware, click the left mouse button upon the object marked red in the objects tree and go to the parameters from the template field.
Click the Distinguish button in the Template field. Image Modified As a result the parameters which values are different from those ones in Axxon PSIMsoftware are moved to the Differences list. Image Modified
Correction (if necessary) of these parameter in Axxon PSIMsoftware for those ones from the template may be performed in two ways:
Click the CorrectRemove differencesbutton in the Template field. Image RemovedImage Added
Go to the Configuration menu on the control panel and select the Correct item. Image RemovedImage Added
The parameter configuration from Axxon PSIMtemplates is now verified and corrected.