Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Core

Registry section

String parameter

Available values

Default

Product version

Parameter in effect

x32: (x32)
x64: (x64)

ChangePort

> = 0

Depends on the port specified for the Client.

4.7.3 and later

Allows changing the port number. For instance, if it is necessary to change port 20900 to 40900, then 20900="40900" string parameter is created.
The change of this parameter can affect the system

x32: (x32)
x64: (x64)

CheckPingPeriod

> 0

 10

4.7.4 to 4.10.2

Sets Server-computer ping period.

Note. In Intellect since version 4.10.3 this parameter is set on the settings panel of the Security zone object

x32: (x32)
x64: (x64)

CheckVersion

0, 1

0

4.7.4 and later

Sets the parameters of Server connection: the version is checked in connected version parameters. If versions do not agree, then there is a corresponding message and no connection

x32: (x32)
x64: (x64)

Core IP Address

IP address

 -

4.7.3 and later 

Address of the computer to the core of which the slave.exe is to connect

x32: (x32)
x64: (x64)

DBAttempts

>=1

 10

4.7.3 and later

Number of attempts to connect to database

x32: (x32)/Debug
x64: (x64)/Debug

DebugLevel

0,1,2,3,4

0

4.7.3 and later

Sets the debug mode:
0 – disabled

1 – information is shown in the process window

2 – information is shown in the process window and logged

3 – extended log is written – it contains module events

4 – extended log is written – it contains module events and parameters

x32: (x32)/Debug
x64: (x64)/Debug

DebugExtension

Any string

LOG

4.7.3 and later

Sets extensions of log files

x32: (x32)/Debug
x64: (x64)/Debug

DebugFlushPeriod

> = 0

500

4.7.4 and later

Sets the update rate for log files (ms)

x32: (x32)/Debug
x64: (x64)/Debug

DebugOptions

Range in decimalsystem: 0-255. 

0x001 (i.e. 1)

4.7.3 and later

Hexadecimal logging in the debug mode. This parameter has a complex structure (bit mask) and it is modified using the Tweaki.exe utility

x32: (x32)/Debug
x64: (x64)/Debug

DebugQueueMaxLines

0 – 2147483647

2000

4.7.4 and later

Specifies max. number of messages in a queue to log file. If there are more than 500 log lines in the queue, then they are to be groomed

x32: (x32)/Debug
x64: (x64)/Debug

DebugSize

>=100

100

4.7.3 and later

Specifies the number of megabytes provided for log. Restricted by disk capacity

x32: (x32)/Debug
x64: (x64)/Debug

DebugTime

 0-2147483647

48

4.7.3 and later

Specifies the number of hours for keeping log files

x32: (x32)/Debug
x64: (x64)/Debug
DebugZipDays>024.7.5 and laterSpecifies the number of days for keeping log files in the gz format
х32: (x32)
x64: (x64)
debug_log0, 1-4.11.2 and later

By default, the key is not created.

The key defines whether all events and reactions all fully logged into the log file.

Note. It is not recommended to use this key on a permanent basis, because with full logging, the size of the log file will constantly increase

х32: (x32)
x64: (x64)
debug_protocol0, 104.11.2 and later

The key creates the DEBUG_PROTOCOL table in the database. All events and reactions are recorded in the table.

Note. When restarting Intellect, the table will be created anew

x32: (x32)
x64: (x64)

defaultconnection

 0, 1

1

4.7.4 and later

Allows setting connections in the architecture only with the computer where the Computer object is created

x32: (x32)
x64: (x64)

DisableProtocol

0, 1

0

4.7.3 and later

Allows disabling protocol

x32: (x32)
x64: (x64)

DisableThreadStatQueue

0, 1

0

4.8.0 and later

 By default the key is not created.

Defines whether the queue statistics is called or not. If the registry key value=1, then the box can not be called.

To call the Queue statistics box, follow the steps:

  • Intellect 4.9.2 and older – press F2
  • Intellect 4.9.3 and later – press Alt+F2 key combination

x32: (x32)
x64: (x64)

InstallFolder


Intellect

4.7.3 and later

Specifies the installation folder

x32: (x32)
x64: (x64)

Language

0x0419

-

4.7.3 and later

Specifies the language to use (0x0419 – English)

x32: (x32)
x64: (x64)

LogIncommingMsg

0, 1

not created

up to  4.8.0

Defines whether logging of incoming events is enabled or not

x32: (x32)
x64: (x64)

LogOutgoingMsg

0, 1

not created

up to  4.8.0

Defines whetheroutgoing reactions (for example, commands) will be logged or not

x32: (x32)
x64: (x64)

LogStatistics

0, 1

not created

up to  4.8.0

Defines whether the statistics is logged or not

x32: (x32)
x64: (x64)

OnlyLocalProtocol

0, 1

0

4.7.3 and later

Only local events are logged

х32: (x32)
x64: (x64)
ProtocolWriteAllEvents0, 104.11.2 and laterDefines whether the events are recorded into the Events protocol

x32: (x32)
x64: (x64)

PeakWorkingSetSizeQuota

>=0

0

4.8.1 and later

Sets RAM limit (MB). When this limit is exceeded, the module that exceeded this limit will be restarted in the restart service

x32: (x32)
x64: (x64)

PhotoCores

Name or IP address 

-

4.7.3 and later

The list of computers (cores) for mailing user photos

x32: (x32)
x64: (x64)

PriorityClass

256,

128,

32768,

32,

16384,

64

 16384

4.7.3 and later

Defines the stream priority:

256 – realtime

128 – high

32768 – Above Normal

32 – normal

16384 – below Normal

64 – low

x32: (x32)
x64: (x64)

ShowCrashMessage

0, 1

0

4.7.5 and later

Create or not the module crash message

x32: (x32)
x64: (x64)

SyncTime

0, 1

0

4.7.3 and later

Defines whether to synchronize time between computers or not

x32: (x32)
x64: (x64)

Topmost

0, 1

1

4.7.4 and later

Sets the splash screen location:
1 – splash screen is topmost
0 – screen is hidden behind other windows

This key is applied for splash screen on the Server/Remote Administrator’s workstation for Intellect versions older than 4.10.0, for versions newer 4.10.1 – both on the Server/Remote Administrator’s workstation and on the Client

x32: (x32)
x64: (x64)

Type_view_dept_log

0,1,2

0

4.7.4 and later

Specifies displaying the  name of department in the log:

0 – do not add:  Ivanov Ivan Ivanovich
1 – add to the beginning:
[Sales department] Ivanov Ivan Ivanovich
2 – add to the end:
Ivanov Ivan Ivanovich [Sales department]

x32: (x32)
x64: (x64)

URAttempts

 0 – 10000

3

4.7.3 and later

Sets the number of attempts to enter the user password

x32: (x32)
x64: (x64)

URDelay

 0 – 10000

60

4.7.3 and later

Sets the delay period (sec) for re-entering the system

x32: (x32)
x64: (x64)

virtualgrabber

0, 1

0

4.7.6 and later

Defines whether it is possible to create  a virtual video capture card or no

x32: (x32)
x64: (x64)

SyncNotEmpty

0, 1

0

4.8.5 and later

Defines the database synchronization algorithm:

1 – fast synchronization algorithm is in use

0 –  standard synchronization algorithm is in use

x32: (x32)\Debug
x64: (x64)\Debug

counter_period

>=0

0

4.9.0 and later

Defines the time period in seconds, in which information about availability of processor, memory and disk is recorded to the log-file. If the value of parameter is 0, this information is not included to the log-file

x32: (x32)\ IntellectRunService
x64: (x64)\ IntellectRunService

RestartIntellectOnLogonDisable

0, 1

0

4.9.0 and later

1 – Intellect installed as a Service is not restarted under the current user even for users belonging to the IntellectUsers group

0 – Intellect installed as a Service is restarted under the current user only if the user belongs to the IntellectUsers group

x32: (x32)\ IntellectRunService
x64: (x64)\ IntellectRunService

CheckUserForRestartIntellectDisable

0, 1

-

4.9.0 and later

0 – Intellect installed as a Service is restarted (when entering the system) under the current user only if the user belongs to the IntellectUsers group

1 – Intellect installed as a Service is restarted (when entering the system) under the current user even if the user doesn’t belong to the IntellectUsers group. The settings of permissions are to be taken into account when using this key. If the permissions are set incorrectly, then some Intellect features can operate incorrectly

x32: (x32)
x64: (x64)

ShowHiddenObjects

0, 1

0

4.9.0 and later

0 – hidden objects corresponding to IntegratedAudioSource and IntegratedVideoSource objects, as well as to Integrated device child objects are not shown in the object tree in Intellect

1 – hidden objects are shown in the object tree in Intellect

Intellect is to be restarted when the key value is changed

x32: (x32)\ IntellectRunService\
x64: (x64)\ IntellectRunService\

InheritServiceEnvironment

0, 1

-

4.9.0 and later

The key is essential for proper operation of Intellect in MS failover cluster

x32: (x32)
x64: (x64)

SortCamsById

0, 1

-

4.8.8 and later

The key is responsible for sorting the list of cameras on the settings panelof the Monitor object.

1 – cameras are sorted by ID

0 – cameras are sorted by names

x32: (x32)
x64: (x64)

EventProcessingThreads

>=0

0

4.9.0

Key reserves the specified number of streams for events processing

4-8Equal to CPU cores number4.11.3 and later

x32: (x32)\Debug
x64: (x64)\Debug

DumpYUV

0, 1

-

4.9.0.959  and later

Key activates the mode of video dump corresponding to compressor. It is required for diagnostics of StreamLabs (motionWavelet7.1) compressor/decompressor problems.

File (or files) with decompressed data will be created by key in the Modules directory. Names of files correspond to the template:
WxH_hv_chunk_№.yuv

W – width
H – height
h – horizontal subsampling
v – vertical subsampling
№ – number of file. If resolution or subsampling are changed the new file openes

For example, file with resolution 640x480 in YUV420 color area will have the 640x480_22_chunk_0.yuv name

x32: (x32)
x64: (x64)

settings_height>0, depends on screen resolution4384.11.3 and laterSets the height of the object settings panel (in pixels)

x32: (x32)
x64: (x64)

settings_width>0, depends on screen resolution6004.11.3 and laterSets the width of the object settings panel (in pixels)
x32: (x32)
x64: (x64)
ATMSendSetup0, 114.9.3 and later

0 – receiving of the SETUP reaction from the ATM object is disabled on the computer where this key is specified

1 – receiving of the SETUP reaction from the ATM object is enabled on the computer where this key is specified

x32: (x32)
x64: (x64)
RegisterF10andF110, 114.9.2 and later

1 – F10 and F11 hot keys are in use to control screen displaying (see Main control panel)

0 – F10 and F11 hot keys are not in use to control screen displaying

Note.When the key is changed Intellect restart is required. 

 To disable F10 and F11 hot keys on the Remote Administrator's workstation, the key is to be created in the  \HKEY_CURRENT_USER\Software\ITV\Intellect registry section.

To disable F10 and F11 hot keys on the Remote Administrator's workstation when operating under the Admin account, he key is to be created in the same registry section as on Server (x32)/(x64)

x32: (x32)
x64: (x64)
DisableF80, 104.10.4 and later

0 –  F8 hot key is in use to call the Execute menu on the main control panel

1 – F8 hot key is not in use

Note. To disable F8 hot key on the Remote Administrator's workstation, the key is to be created in the  \HKEY_CURRENT_USER\Software\ITV\Intellect registry section.

To disable F8 hot key on the Remote Administrator's workstation when operating under the Admin account, he key is to be created in the same registry section as on Server (x32)/(x64)

x32: (x32)
x64: (x64)

check_digital0, 104.8.0 and later

When the key value = 1, video or archive period is exported from the Monitor interface using the admin password

x32: (x32)
x64: (x64)
CONNECT_ATTEMPTS>=114.9.4 and laterThe key sets the number of attempts to connect the Client to Server. The key is specified on the side of the Client
x32: (x32)
x64: (x64)
FLUSH_TIMER_TIMEOUT>0

By default the key is not created, the value is 10.

4.9.4 and later

The key specifies maximum waiting time (in milliseconds) before sending data over the network.

The higher the value of this parameter, the more productive the system is (due to decreasing resources when sending a large amount of small messages).

However, time of response to events can also increase
x32: (x32)
x64: (x64)
UnloadDelay0 to 60000 ms50004.9.5 and later

The key sets the delay between disabling Guardant and unloading Intellect.

The delay is essential for the FORCED_OFF event generation of the SLAVE object and in case this event is used in scripts or programs, these scripts and programs are executed.

If UnloadDelay = 0, unloading is performed without any delays, i.e. script/program in which the specified event is used, cannot execute
x32: (x32)
x64: (x64)
SortSubItems0, 104.9.5 and later

The key is for specifying the way of sorting objects in the tree:

0 – sorting by name

1 – sorting by ID

Note 1. If sorting by name is chosen, and there are numbers in the object name, then the objects will be sorted in alphabetical order. For example, an object with the name "115" will be above the object with the name "15", because in the name "115" the second number is 1, and in the name "15" the second number is 5.

Note 2. This key also affects the sorting of objects in the tree when adding the objects to a layer in the Map Editor utility

x32: (x32)
x64: (x64)
ShowSmallBarAlways0, 104.10.1 and later

The key enables displaying the main control panel of Intellect on the screen.

0 – the main control panel is displayed when pointing to the upper right corner of the screen

1 – the main control panel is always displayed in the upper right corner of the screen
x32: (x32)
x64: (x64)
UpdateProtocolPeriod> 0-4.10.2 and later

Sets time period (in days) of storing the change protocol in the database.

The storing period is counted from the last recording or starting from the current time depending on the value of the ClearProtocolFromCurrentTime key (see above).

Recordings storing period of which has expired are deleted at midnight every 24 hours in case the license is activated
x32: (x32)
x64: (x64)
permissible_memory_limit>0-4.10.3 and laterThe key sets the occupied memory threshold, reaching which the core starts receiving messages with a delay. The key should be used when due to excessive memory consumption, the module shuts down
x32: (x32)
x64: (x64)
MsgCompressOn0, 104.10.3 and later

The key enables the compression of transmitted messages:

0 compression is disabled

1 messages from the cores are sent compressed (zip with maximum compression). Compression allows reducing the network load

Note. If the key value = 1, the Web-Server doesn't work, because the Web-Server doesn't recieve compressed messages

x32: (x32)
x64: (x64)
user_card_info_on0, 10Intermediate versions 4.10.3

The key is used with the ACS/FAS integration modules that are the part of ACFA Intellect. It enables displaying the access card number for all events associated with the cards in the Event Viewer.
0 – the access card number is not displayed in the Event Viewer
1 – when an event comes from the ACS device, the param1 parameter is interpreted as an access card number and is displayed in the Event Viewer in the Card column. This column is automatically added to the Event Viewer window when the first such event is received.

Note. In the released version 4.10.3 to show and hide the Card column use the Hide Card checkbox – see Event viewer parameters

x32: (x32)
x64: (x64)
CriticalErrGui0, 104.10.3 and laterIt enables displaying messages about database connection errors regardless the debugging mode (see the description of the Debug key and Selecting and enabling the debug mode of Intellect software section).
0 – messages about database connection errors are displayed only at Debug 4 debugging levels
1 – messages about database connection errors are displayed regardless the selected debugging level
x32: (x32) 
x64: (x64)
IntellectCloseTimeout>0600004.8.3 and laterIt sets Intellect close timeout in milliseconds. If intellect.exe process does not close during this timeout, then it is terminated forcefully. If there is no key, then timeout is 60 seconds
x32: (x32)
x64: (x64)
SaveIncommingMsg0, 104.7.8 and later

It enables recording of incoming messages to log files for started modules. The file name looks like <module name>.exe.cd.log.

These files are stored in the same folder as the executed module file, for instance, for intellect.exe the intellect.exe.cd.log file is stored in the Intellect installation directory and for VMSScript.exe the VMSScript.exe.cd.log file is stored in the Modules folder.

When the size of the log file exceeds 4 GB, it is archived to the backup file with .bak extension – <module name>.exe.cd.log.bak. This is necessary to avoid module overload.

Note. The log file is rewritten when Intellect is restarted.

0 – recording of incoming messages is disabled

1 – recording of incoming messages is enabled

x32: (x32)
x64: (x64)
BackupFolderAddress of a local or network folder-4.7.6 and laterSpecifies the address of the folder to save a backup copy of the database created by a macro or using the idb.exe utility.
For example, C:\Documents and Settings\AVP\Desktop\Backup

If the database copy is to be stored on the network disk, then the UNC path to the network folder (with the recording access) is to be specified on the disk in the \\ServerName\ShareName format. Take into account the fact that all network resources that require additional authentication are to be enabled using the same username as for running the SQL Server service.

See also Creating the database backup copy

x32 and x64:

HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Winlogon

ShellAny text valueexplorer.exe4.10.5 and laterIf the key value contains the "explorer" string (for example, the default value, "testexplorertest" or "123explorertest125" values), the Save button is displayed in the About program... window. Otherwise, the Save button is hidden
x32: (x32)\ IntellectRunService
x64: (x64)\ IntellectRunService
IntellectUserGroupAny text value
from 4.10.0If Intellect is installed as a Service, and you need to use a user group other than IntellectUsers, then specify the required user group name in this key
x32: (x32)
x64: (x64)
monitor_refresh_delay10 -300003000from 4.10.5

The key sets a period in milliseconds to update video on Video Surveillance Monitors of the Clients after Failover Service has transferred configuration.

If the key value is less than 500, the monitors are updated regardless of the number of cameras.

If the key value is more than 500 and the number of cameras on the monitor is more than 64, the update does not occur while the System Settings dialog box is open

x32: (x32)
x64: (x64)
DisableUpdateProtocol0, 10from 4.7.5The key disables the filling of the UPDATE_PROTOCOL table storing information about changes of Intellect object settings (except the User objects).
0 – the UPDATE_PROTOCOL table is filled
1 – the UPDATE_PROTOCOL table is not filled
x32: (x32)
x64: (x64)

max_disp_menu_items

>050from 4.10.5If the number of screens assigned to a computer is larger than that specified in the key, scrolling the list of screens with the mouse wheel becomes available (if the size of the list is larger than the size of a computer monitor).

The key is set on each Server and Client where this function is required
x32: (x32)
x64: (x64)
URM_ProcessWait>010000from 4.10.5

The key sets time period in milliseconds to wait for the Client to stop before aborting the Video.run process.

The key should be created on the Clients

x32: (x32)
x64: (x64)
show_responsible0, 10from 4.10.5

The key enables the display of users responsible for the region (if assigned) in events from objects related to the regions:

  • In the Event Log – in the Add.info field
  • In the Operator protocol – in the event box next to the name of the region
  • On the Map – in the Output window on the Object Info tab

The key is created on the Server

x32: (x32)
x64: (x64)
NotifyExpireLic0, 10from 4.10.5The key enables the event showing the days left to the license expiration (see SLAVE)
x32: (x32)
x64: (x64)
sync_timeout>0600from 4.10.5The key sets the time period in seconds allocated for synchronizing the database when starting Intellect software. The key must be created on the Server, where synchronization with another server occurs. See also Database synchronization setup
x32: (x32)
x64: (x64)

ShowPanelByKey

0, 10from 4.10.11

The key disables the display of the Main control panel by hovering the mouse cursor in the upper right corner of the screen. Having the key is set to 1, use the F12 hotkey to call the Main control panel

x32: (x32)
x64: (x64)
IntegrityCheck0, 10from 4.11.0

Enables distribution integrity check when starting Intellect software package. The following files are checked:

  • Intellect.exe
  • Intellect64.exe
  • Slave.exe
  • Modules64/Slave.exe

If any of them is missing or changed, the message "The integrity of the distribution package is broken. Reinstall Intellect" is displayed in the launch window, and the Intellect start interrupts

x32: (x32)\Display
x64: (x64)\Display
DISPLAY_MAX_NUM1-1000500from 4.10.5The key sets the maximum number of Display objects that can be assigned to one computer
x32: (x32)\
x64: (x64)\
RestPort0 – 6553510112from 4.10.1 to 4.10.2

Sets the port through which Intellect receives events and reactions via HTTP request. See also Sending reactions and events to Intellect using HTTP request.

The key is discontinued starting from Intellect 4.11.1. The port is set on the Web server object settings panel – see Setting the parameters of connecting Clients to the Web-server

0from 4.10.3 to 4.11.0
x32: (x32)\
x64: (x64)\
ADSyncOnStart 0, 10from 4.10.5

The key enables synchronization with Active Directory when starting Intellect software.

0 – synchronization with AD when starting Intellect is disabled

1 – synchronization with AD when starting Intellect software is enabled

x32: (x32)\
x64: (x64)\
NgpMode0, 10from 4.11.1

The key enables the joint operation of the Intellect software package and the Axxon Next software package.

0 – joint operation is disabled

1 – joint operation is enabled

x32: (x32)\
x64: (x64)\
cur_monitor>0not setfrom 4.11.2

The key specifies the number of the physical monitor on which the Main Control Panel should be displayed. The key can be used both for the Intellect Server/RAW configuration, and for the Client configuration.

Monitors are numbered left to right, top to bottom, regardless of system numbering.

Important! The numbering of monitors starts from 0. For example, set the key to 0 to display the Main Control Panel on the 1st physical monitor; set to 1 to display on the 2nd monitor, etc.

By default, the Main Control Panel is displayed on the Primary monitor selected in the system screen options

x32: (x32)\Macro

x64: (x64)\Macro
UseHotKeys0, 11from 4.11.3

The key disables hot keys for macros.

0 – hotkeys in macros are disabled

1 – hotkeys in macros are enabled

х32: (x32)
x64: (x64)
SocketReadSize>032768from 4.8.3

The key sets the size of the buffer to receive the TCP transport layer in bytes. Examples of values: 262144 (0.25 MB), 1048576 (1 MB), 10485760 (10 MB). Used together with the SocketWriteSize parameter

х32: (x32)
x64: (x64)
SocketWriteSize>032768from 4.8.3

The key sets the buffer size to send the socket of the TCP transport layer in bytes. Examples of values: 262144 (0.25 MB), 1048576 (1 MB), 10485760 (10 MB). Used together with the SocketReadSize parameter

х32: (x32)\InstallPropertyInfo
x64: (x64)\InstallPropertyInfo
INSTALL_AS_SERVICE0, 10from 4.11.3

Enables Intellect installation as a Service.

0—standard Intellect installation

1—Intellect will be installed as a Service

х32: (x32)
x64: (x64)
core_module_nameintellect.exe, intellect64.exeintellect.exefrom 4.11.3.4160

Sets the executable file of the program module if Intellect is installed as a Service.

intellect.exe—the intellect.exe program module is started when Intellect Core Server service is started

intellect64.exe—the intellect64.exe program module is started when Intellect Core Server service is started

TABLE OF CONTENTS


Telemetry

Registry section

String parameter

Available values

Default

Product version

Parameter in effect

x32: (X32)\TELEMETRY
x64: (x64)\TELEMETRY

Delay

> = 0

250

4.7.3 and later

Defines the delay (ms) when sending commands to the camera. This key is essential for grooming the stream of commands to the device as some devices can be blocked because of too many commands and cannot process the information.

This parameter is not supported by IP cameras

x32: (X32)\TELEMETRY
x64: (x64)\TELEMETRY

JoysticThreshold

> = 0

5

4.7.6 HOTFIX and later

This parameter sets the joystick trigger threshold: the less the number is, the more sensitive joystick is.

0 value is not recommended to be used, as commands can be sent randomly. When the value is too big, the joystick becomes rotation-insensitive

x32: (X32)\TELEMETRY
x64: (x64)\TELEMETRY

PriorityDelay

> =  0

30000

4.7.3 and later

Defines the priority delay (ms)

x32: (X32)\TELEMETRY
x64: (x64)\TELEMETRY

UseBoschOSRD40

0, 1

-

4.8.4 and later

Enables presets saving for Bosch-Autodome control protocol

x32: (X32)\TELEMETRY
x64: (x64)\TELEMETRY

PnPJoystick

0, 1

0

4.8.3 and later 

The key defines whether to restart Intellect after connecting a joystick:

0 – Intellect is to be restarted after connecting the joystick
1 – Intellect is not to be restarted after connecting the joystick

x32: (X32)\TELEMETRY
x64: (x64)\TELEMETRY

Zenable

0, 1

1

4.7.7 and later 

The key is in use with joysticks (e.g., Logitech Attack 3) where the telemetry control operates incorrectly because of shifted Z axis. Z axis is disabled when the parameter value is 0. Z axis is enabled when the parameter value is 1

x32: (X32)\TELEMETRY
x64: (x64)\TELEMETRY
ZoomSpeed8500,114.9.0 and later 

The key is used in order to set the zoom step when panasonic-850 telemetry protocol is in use:

1 – zooming with 50% step of max. possible

0 – zooming with 20% step of max. possible

x32: (X32)\TELEMETRY
x64: (x64)\TELEMETRY
Zdirection0, 104.7.6 and later 

The key is responsible for coordinate move in the Z-direction

x32: (X32)\TELEMETRY
x64: (x64)\TELEMETRY
Ydirection0, 104.7.6 and later 

The key is responsible for coordinate move in the Y-direction

x32: (X32)\TELEMETRY
x64: (x64)\TELEMETRY
Xdirection0, 104.7.6 and later 

The key is responsible for coordinate move in the X-direction

x32: (X32)\TELEMETRY
x64: (x64)\TELEMETRY
WaitDelay>=004.7.5 and later If a joystick sends the messages about its state to Intellect too frequently and Intellect has no time to process these messages, then this parameter is in use – it allows calling the signal handler less frequently. For instance, this parameter should be used with Axis 295 joystick. The best parameter value is to be chosen. The value should match the 100 – 300 range  
x32: (x32)\TELEMETRY
x64: (x64)\TELEMETRY
TelemetryDirectCommand0, 114.9.8 and later

The key specifies way of  command transmission to telemetry:

1 – telemetry server is connected to video servers and sends commands to devices

0 – telemetry server sends commands to the Intellect core which send them to devices

See also description of the MonitorToTelemetryDirectCommand key below

x32: (x32)\TELEMETRY
x64: (x64)\TELEMETRY
MonitorToTelemetryDirectCommand0, 104.9.8 and later

The key specifies way of transmission telemetry commands while control from the Monitor:

1 – telemetry server is connected to video servers and sends commands to devices while telemetry control from the Monitor

0 – telemetry server sends commands to the Intellect core which send them to devices while telemetry control from the Monitor

The key is in use with the TelemetryDirectCommand key to provide smoother telemetry control. Recommended values of these keys:

TelemetryDirectCommand = 1 (default value)

MonitorToTelemetryDirectCommand = 1 (attention: default value is 0)

Attention! Client, server and camera should be in one subnet without video gate when using these registry keys. Otherwise, systemwillnotoperate
x32: (x32)\TELEMETRY
x64: (x64)\TELEMETRY
SendEventToCore0, 104.10.0 and later

The key is to enable the function of sending events to Intellect core when controlling PTZ. This function is essential for PTZ control audit.

1 – when sending any reaction of TELEMETRY object the corresponding event is generated

0 – during PTZ control events are not generated
x32: (X32)\Video\CommonPresets
x64: (x64)\Video\CommonPresets
ONVIF0, 104.10.0 and later

The key enables presets created on the camera in Intellect. The function is only available when camera is connected via ONVIF protocol and only if video server settings are selected when adding a Video capture device using the Camera discovery tool and the Use device settings checkbox is set unchecked on the settings panel of the Video Capture Device object.

0 – presets created on the camera are not used in Intellect

1 – presets created on the camera are in use in Intellect. The features are listed below:

  1. The preset ID on the camera is to be the same as the preset ID in Intellect or differ by 1 depending on the camera features (see item 2)
  2. As preset numeration starts differently on various cameras (with 0 or 1), then preset numbers can differ by 1 in Intellect. If the numeration on the camera starts with 0, then numeration in Intellect is the same. If the numeration on the camera starts with 1, then numeration in Intellect is greater by 1 (for instance, the first preset on the camera corresponds to the second in Intellect and the first in Intellect is not active)
x32: (X32)\TELEMETRY
x64: (x64)\TELEMETRY
panas850_stop_dublicates>0-4.10.2 and laterThe key is in use if the camera rotation is not stopped when telemetry is controlled over Panasonic-850 protocol. The key specifies how many times the stop command is to be duplicated
x32: (X32)\TELEMETRY
x64: (x64)\TELEMETRY
DisableInternalJoystick0, 1-4.11.0 and later

The key enables the old mechanism for connecting and controlling joysticks using Windows tools.

1 – the joystick is controlled by Driver Pack driver

0 – the joystick is controlled by Windows built-in driver

By default, joysticks should be connected the Camera discovery tool as a Control Device.See also Configuring the joystick for telemetry control.

DO NOT set the key to 0 if the Control Device object is created for the joystick.

DO NOT set the key to 1 if the Control Panel object is created for the joystick

...