- Go to the configuration panel for an Agent of Control object.

- Click the Logging subsystem... button.
- In the dialog box that opens, specify the following parameters:

- Auxiliary characters: To log transport-level auxiliary characters, select this check box.
- Alarm events: To log alarms (activation of vibration sensor, temperature sensor, or forcible entry sensor), select this check box.
- System status: To log events related to the system state, select this check box.
- Intellect Axxon PSIM messages: To log messages from IntellectAxxon PSIM, select this check box. Information is saved in the folder to which the software was installed, in the file video.log.
- Archiving period (h): Allows archiving the log file at the specified interval (in hours). Archives are saved in the DATA subfolder, with the following name format: namelog_yymmddhhmmss.gz, where
- namelog is the name of the log file being archived;
- yy is the year of archive creation;
- mm is the month of archive creation;
- dd is the day of archive creation;
- hh is the hour of archive creation;
- mm is the minute of archive creation;
- ss is the second of archive creation.
- File size (MB): Sets the threshold size (in megabytes) for the log file after which the file is archived. This setting overrides the value in the Archive period (h) field.
- Keep archives for (months): Sets the length of time for which to store the log file archive, in months (between 1 and 24). Archives that are older than the specified number of months are deleted.
...
{"serverDuration": 105, "requestCorrelationId": "6f02f9b41a82d36d"}