  1. In the root directory of the distribution package, run the setup.exe executable file.
  2. To continue the installation process, click Next.
  3. Read the terms of the license agreement carefully. Then set the radio button to I accept the terms of the License agreement and click Next.
  4. Set the Server of control installation type and click Next.
  5. If Axxon PSIM software is installed as a service, and it is necessary that Monitoring PSIM is also installed as a service, then set the Install Monitoring PSIM as a service checkbox and click Next (for details, see General information about Monitoring PSIM PSIM as a Service).
  6. Select the database MS SQL Server and specify the authorization parameters for connection. For details, see Installation of Axxon PSIM™ as a Server/Remote Administrator's workplace.. To continue the installation process, click Next.

    Info
    titleNote.

    In the Select database Server from the drop-down list field specify the 127.0.0.1 value instead of computer name or "(local)" value, e.g. "127.0.0.1\SQLEXPRESS". Otherwise Server of control will lose connection with its local database when the network cable is disconnected.

  7. In the Database field specify the name of the database or select it on the right part of the window in the list of databases, which are created in the server, and click <<. Then click Next.

    Info
    titleNote.

    By default, the name of the database is "MonitorSSTV" and its files will be stored in the SQL Server folder.

  8. Click Install to start the installation process. 

  9. As a result, the necessary components of the Monitoring PSIM software package will be copied to hard drive of your computer.
  10. After all software components are successfully copied on your hard drive, the message about the completion of the installation process will be displayed. Click Finish.