Go to documentation repository
...
Note | ||
---|---|---|
| ||
Every time when ATM-Intellect Pro starts, it checks for a Backup folder at the root of the disk on which Intellect software is is installed. This folder is created if it does not exist already. It is forbidden to delete this folder. |
Info | ||
---|---|---|
| ||
ATM - Intellect components (ATM-Intellect Pro and ATM-Intellect Workstation) can work in a distributed configuration, while all the listed objects see where each of them is installed and can be configured. |
...
The Automatic pause of recording by cameras checkbox (3) is set by default, so that the scripts from the code are executed automatically. To fine-tune these scripts, use the SleepAfterDisarm and SleepAfterRecStop registry keys (see Vertical solutions). When the checkbox is clear, the scripts described here can be used to pause recording by cameras.
Create the required number of child Surveillance Object objects on the basis of the ATM-Intellect Pro object.
Info | ||
---|---|---|
| ||
The Surveillance Object object name cannot contain the following characters: underscore "_", backslash "\", angle brackets ">" and "<", single quote "'". |
You also need to create Video Capture Device, Camera and Sensor objects corresponding to the connected equipmenthardware. Creation and configuration of these objects is described in the INTELLECT Software Package. Installing and configuring security system components.
Objects creation is completedCreating the necessary objects in the hardware tree is complete.