Page History
Integration POS Intellect can be integrated with POS server, which can receive events from all pos POS terminals (or filling fuel dispensers of gas stations) and resend them to the video surveillance system using one logic connection is allowablelogical connection using the SplitterPlugin plugin.
The A separate camera (cameras) should must be added attached to the each POS terminal (gas station filling stationcolumn).
In this case, the package must contain the StationNumber or TerminalId tag is required in the package.
Code Block |
---|
<StationNumber>ID</StationNumber> |
Code Block |
---|
<TerminalId>ID</TerminalId> |
where, ID—unique identifier of the POS terminal Where ID - unique identifier of POS (filling station).
Example An example of interaction with the POS server:
One POS is installed in the filling station and data are sending There is one POS terminal at the gas station, and data is sent to the video surveillance system using this POSthrough it. 3 filling stations fuel dispensers are connected to this POS . The separate camera is added to the each filling station terminal, each fuel dispenser is monitored by a separate camera.
To realize implement video monitoring in as part of the POS - Intellect software it's required , you need to create 3 POS-terminal objects in the objects system object tree, assign cameras to the each POS-terminal object and assign POS-terminal to the corresponding POS terminal.
Then, the POS terminal will send the data to the mixforward.exe utility embedded to included in the POS - Intellect software, which will analyze the data and resend redirect them to the created system objects.