The list of object names, reactions and events used while programming in Axxon PSIM software software can be got with the help of ddi.exe tool. See the description of the main system objects reactions in the Description of system object reactions.

The ddiDdi.exe tool is started in one of the following ways:

  1. StartAxxon PSIMSystem configuration.

    Info
    titleNote

    DdiThe ddi.exe tool is available in the Start menu with the following types of Axxon PSIM installation: Server, Administrator’s workstation and Workstation for monitoring.


  2. In the Tools folder of Axxon PSIM installation folder.

...

  1. In the tool, openpsim.ddi file.
  2. Select the DDI tab on the left (1). The list of system objects is displayed here.
  3. In the DDI tab, select the object which events and reactions are to be viewed (2).
  4. To view the name of the selected object, go to the Names tab (3).
  5. To view the list of events for the selected object, go to the Events tab.
  6. To view the list of reactions for the selected object, go to the Reactions tab.

The See the detailed information on working with ddi.exe tool is given in Administrator's Guidein the Editing psim.dbi and psim.ext.dbi database templates using the ddi.exe utility.

Info
titleNote.

If the Sensor is armed, then at the Sensor switching on/off the Alarm event appears depending on the alarm mode setting (see the Creating and configuring the Sensor system object section of the Installing and configuring security system components guide). If the Sensor is disarmed, the Closed/Opened events appear correspondingly.

...