Before updating the Axxon PSIM software, it is recommended to create a configuration backup copy and expand it after getting the new version installed, if necessary.
Tip |
---|
The full articles: |
You can update the Axxon PSIM software on top of the installed version without preliminary removing only in case if the second version number corresponds to both of the installed and new versions (i.e. you can update from 41.101.x to 41.101.y (x<y) or from 41.112.x to 41.112.y (x<y), but you cannot update from 41.10 1 to 41.112).
Tip |
---|
The full article: Updating Axxon PSIM™ software |
Remove the files left in the Axxon PSIM software installation directory (by default, C:\Program Files (x86)\Axxon PSIM\).
Note | ||
---|---|---|
| ||
To save the license, you need to copy the ‘Axxon PSIM‘psim.sec.’ activation key into the temporary storage before removing the files from this folder. |
Run the Axxon PSIM software new version installation.
MS SQL Server 2014 is being supplied as the part of the Axxon PSIMTip |
---|
The full article: Installing Axxon PSIM™ software |
...
title | Important! |
---|