Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Commandcommand description

Parameters

Description

"REMOVE" – removes camera from monitor.

cam<>

ID of camera in the settings tree which is to be removed from monitor

show<>

Optional parameter. Possible values:

0 – do not update the layout in the Monitor after removing the camera. There may be empty space not occupied by Video surveillance windows

1 – update the layout in the Monitor after removing the camera to minimize empty space

"REMOVE_ALL" – removes all cameras from monitor

-

-

"STOP_VIDEO" – stops video flow of camera

cam<>

ID of camera in the settings tree video flow from which is to be stopped

"REPLACE" – removes all cameras from monitor and triggers the specified camera

slave_id<>

Name of computer to which monitor belongs, it is possible to place owner in script

cam<>

ID of camera in the settings tree which is to be displayed in the monitor

name<>

Name of camera which is to be displayed in the bottom-left corner

audio_type<>

-

audio_id<>

-

arch_id<>

-

control<>

0 only archive viewing, 1 – it is also possible to control (arming/disarming, record)

"ADD_SHOW" – adds cameras on the monitor

Note. See also PLACE_CAM_IN_LAYOUT_CELL

cam<>

ID of camera in the settings tree which is to be displayed in the monitor

name<>

Object name which is to be displayed in the bottom-left corner

arch_id<>

-

control<>

0 only archive viewing, 1 – it is also possible to control (arming/disarming, record)

gate_id<>ID of the video gate to receive video through. The corresponding camera must be added and configured in this video gate - see Selecting and configuring the cameras for the Videogate module
slave_id<>ID of the computer to which the command is applied

"ACTIVATE_CAM" – activates camera

cam<>

ID of camera in the settings tree which is to be activated

"ARCH_FRAME_TIME" – search of video archive by date and time

cam<>

-

date<>

-

time<>

-

mode<>

Can take the following values:

0 – Video Gate, if it is set (if not set, then the archive of the Video Server is searched)

1 – Video Server

2 – Backup archive

10 + Object ID External storage in the Monitor object settings panel (normally 11) – external storage

"SETUP" – sets parameters of monitor

no_update<>

-

overlay<>

Disable the mode of speed-up displaying

x<>

Coordinate of top-left corner (0 – 100)

y<>

Coordinate of top-left corner (0 – 100)

w<>

Size in horizontal direction (0 – 100)

h<>

Size in vertical direction (0 – 100)

max_cams<>

Maximum allowable number of cameras on the monitor

min_cams<>

Minimum allowable number of cameras on the monitor

compress<>

-

panel<>

Show control panel (0 – disabled, 1 – enabled)

panel_type<>

-

s<>

-

layout<>

-

gate<>

-

map_id<>

-

enable<>

-

topmost<>

1 – show screen always on top

type<>

Type of Monitor object

allow_move<>

Allows moving of window

arch_id<>

Archive ID

cycle<>

Delay while auto scrolling (1 – 20 sec)

flags<>

Flags

name<>

Name of object

overlay<>

Enable the mode of speed-up displaying. (0 – no speeding-up, 1 – “overlay mode” speeding-up, 2 – “DirectDraw mode” speeding-up)

tel_prior<>

Telemetry priority

gstream_version<>

If the value is not set, the function for stream auto select is disabled

If the value is minBPS, then the stream for displaying is selected automatically as described in Configuring an auto select of video stream for displaying

"ACTIVATE" – activates control panel of monitor

user_id<>

User ID

panel_active<>

-

"DEACTIVATE" – deactivates control panel of monitor

-

-

"EXPORT_FRAME" – exports frame in JPG-file

cam<>

-

file

-

"KEY_PRESSED" – controls buttons of video surveillance monitor and video records archive


number<>

-

cam_id<>The ID of the camera to the Video surveillance window of which the command is to be applied. If the identifier is not specified, the command is applied to the active Video surveillance window (see Active Surveillance window)

key<>

Possible values:

"ARCH_EDIT_DATE" – change date of search by archive;

"ARCH_EDIT_TIME" – change time of search by archive;

"ARCH_EDIT_ENTER" – enter changes of values in archive;

"ARCH_EDIT_ESCAPE" – cancel editing of archive;

"ARCH_EDIT_BACK";

"ARCH_EDIT_REPLACE";

"WINDOW_ZOOM_IN" – expand window of video surveillance;

"WINDOW_ZOOM_OUT" – hide window of video surveillance;

"ZOOM_IN" – image incoming;

"ZOOM_OUT" – image removal;

"CYCLE_REW" – scrolling back of video surveillance windows;

"CYCLE_FF" – scrolling straight of video surveillance windows;

"LEFT" – move the frame left in the Zoom mode;

"RIGHT" – move the frame right in the Zoom mode;

"UP" – move the frame up in the Zoom mode;

"DOWN" – move the frame down in the Zoom mode;

"MODE_VIDEO" – video surveillance mode;

"MODE_ARCH" – mode of archive video records playback;

"MODE_ARCH2"- mode of archive video records playback 2;

"MASK_SHOW" – show mask;

"MASK_HIDE" – remove mask;

"ARM" – arm camera;

"DISARM" – disarm camera;

"REW" – rewind;

"PLAY" – play;

"PLAY_NONSTOP" – non-stop playback;

"PLAY_FAST" – speed up video record playback;

"FF" – forward wind;

"RECORD" – record;

"RECORD_MIC" – record from microphone;

"STOP" – stop;

"REC_STOP" – stop record;

"PAUSE" – pause;

"MIC_ON" – microphone On;

"MIC_OFF" – microphone Off;

"PRINT" – print the frame;

"SELECT_LAYOUT" – control layout of video surveillance monitor;

"START_CYCLE_FF" – enable function of slide show of video surveillance windows frontwards. Period of switching video images is specified while configuring the Monitor interface object (see the Administrator’s Guide, Configuring the display mode of camera windows);

"STOP_CYCLE" – stop of slide show of Video surveillance windows;

"EXPORT_DO" – open the AviExport tool for backgroung background export (see The AviExport utility);

"PROTECT_DO" – open the dialog box to create a bookmark (see Create a bookmark);

"PROTECT_VIEW" – show the bookmark list (see List of bookmarks)

"START_AVI_EXPORT" – starts video export

Note. See the example as follows

start<>

Start time

finish<>

End time

avi_path<>

Path to created file

cam<>

Camera ID

"STOP_AVI_EXPORT" – stops video export

monitor<>

Number of monitor

"START_AVI_SCHEDULE" – start bookmarks export--
"STOP_AVI_SCHEDULE" – stop bookmarks export--

"CONTROL_TELEMETRY" – Telemetry control.

See Mouse PTZ control section in Operator's Guide
cam<>ID of camera where mouse PTZ control is to be enabled or disabled
on<>

0 – disable mouse PTZ control

1 – enable mouse PTZ control
"SET_REC_RESTART" – set recording restart when entering the archive--
"RESET_REC_RESTART" – reset recording restart when entering the archive--
"SET_ARCH_ENTER_PAUSE" – enable playback pause when entering the archive--
"RESET_ARCH_ENTER_PAUSE" – disable playback pause when entering the archive.--
"DISABLE_TELEMETRY" – disable telemetry control from Video surveillance monitor--
"ENABLE_TELEMETRY" – enable telemetry control from Video surveillance monitor--
"INCREASE_VIEW" – increase camera window size in the Video surveillance monitorcam<>Camera identifier
"DECREASE_VIEW" – decrease camera window size in the Video surveillance monitorcam<>Camera identifier
"SHOW_LAYOUT" – show layout with the specified ID.layout_id<>Layout ID in database

"GO_LIVE" – switch all cameras on the monitor to live video mode.

--

"GO_ARCH" – switch all cameras on the monitor to archive mode.

arch_time<>

Optional parameter. Sets the time position in the archive in the format DD-MM-YY HH:MM:SS. By default, the archive is positioned on the last record

"SAVE_AS" – export selected archive fragment--

PLACE_CAM_IN_LAYOUT_CELL – add camera to the specific cell on the specific layout on the Monitor





cam<>ID of camera in the object tree which is to be displayed in the monitor. If the parameter value is incorrect, for example, 0 or -1, then the corresponding cell will be hidden
layout_name<>ID or name of the layout to add camera on
cell<>

The number of the cell on the layout to which the camera should be added. Cells are numbered from top to bottom left to right, starting from the top-left corner of the layout.

Important! Cells are numbered starting from 0.

If some other camera has already been added to the specified cell, it will be replaced

SET_TITLES – show captions over a video image in any display mode. Such captions are not archived and are displayed until CLEAR_TITLES command is applied or Monitor is resetcam<>The ID of the camera to the Video surveillance window of which the command is to be applied
titles<>The caption text that should be displayed. Use '\r' to break the line
title_id<>Captioner ID

CLEAR_TITLES – disable the captions created with the help of the SET_TITLES command

cam<>The ID of the camera to the Video surveillance window of which the command is to be applied
title_id<>Captioner ID

...