Additional objects of the system are as followsinclude the following.

The objects under the Hardware tab:

  1. Videogate channels video from videoservers video servers to remote workstations.
  2. Web-server enables to configure monitoring video streams transmitted with the TCP/IP protocol in Internet browser window.
  3. Backup archive enables to configure archive file backup to local and network discs and USB drives.
  4. Control panel is used for configuring analog PTZ devices.
  5. Detection zone allows to configure detectors that provide automatic video image analysis to recognize events occurring within the observed scene.
  6. Titles Database – here you can Captioner allows to configure how the content of receipts (i.e. titlescaptions) are is superimposed over video image.
  7. SNMP service allows you to configure the SNMP-notifications for operator.
  8. Operator query panel allows you to model user dialog windows with any static or dynamic content.
  9. Alarm Message Window – here you can allows to configure the interface window used to inform operator of registered alarms and system events.
  10. Voice notification service is used to configure audio notification of alarm events registered by the system.
  11. Voice Message Service is used to configure voice messages transmitted over telephone lines.
  12. Short Message Service allows to configure SMS messages delivery to cell phones of the system users.
  13. Mail Message Service allows to configure email messages delivery to the system users.
  14. System restart service enables you to configure rebooting Axxon PSIM modules if they are not responding.
  15. Keyboard allows to configure the special keyboard for on-the-fly control of basic Axxon PSIM object functions.
  16. Event counter allows to configure which events within specified time span will be counted.
  17. Data replication serviceallows to configure replication of archive from servers using the removable media.

  18. PS-RTP Server – configuration of allows to configure interaction between third-party software and Axxon PSIM via GB28181 protocol.
  19. rtsp Server – configuration of  RTSP Server allows to configure sending both live video and Axxon PSIM archive over RTSP protocol.
  20. Web server 2.0 – configuration of allows to configure video surveillance using mobile clients.
  21. Edge storage – configuration of allows to configure access to the archive in onboard storage of IP device.
  22. Backup audio archive – configuration of allows to configure backing up the archive recorded with audio.
  23. Sound notification allows to configure voice notification configuration.
  24. IIDK interface allows to configure control over elements in the third-party software.
  25. Failover – switching is used to switch to standby servers upon the failure of the previously active servers. 
  26. Failover manager – configuration of allows to configure the maximum number of failovers.
  27. Audio playback card – configuration of allows to configure the connected audio card with the audio output.
  28. Loud speaker allows to configure audio playback configuration.
  29. LDAP service – importing is used to import users from LDAP address book to Axxon PSIM database.
  30. VMDA metadata storage – configuration of is used to configure storing motion trajectories of objects in the field of view of a camera.

The objects under the Interfaces tab:

  1. Panel of Backup archive – here you configure is used for configuring the interface object for backing-up your data.
  2. External window is created under the Screen object to configure the windows of external applications.
  3. Telemetry control panel allows to configure PTZ controls, focusing and zooming controls for selected video cameras.
  4. Captions search is used to configure queries for the titles database.
  5. HTML interface – configuration of is used for configuring the interface object that allows displaying web pages.
  6. Live sound switch – configuration of is used for configuring the interface object that allows directing audio signal coming from any sound source (microphone) to any sound detector (loudspeaker) for playback.
  7. Configuration check – run is used for running the configuration check utility.
  8. Operator protocol – configuration of is used for configuring the interface object for processing events coming from security system objects and searching in the event log.
  9. Scene– configuration of is used for configuring the interface object for panoramic video displaying.

...

  1. Macro is used for setting up interactions of the objects that do not have the functionality to perform the required tasks.
  2. Program allows to set up scenarios if the Macro object does not offer the functionality to perform the required tasks. It is implemented using a programming language embedded in Axxon PSIM.
  3. Script allows to set up scripts if the Macro object does not have the functionality to perform the required tasks. It is basically a code written in JScript.
  4. Time Zone is one of the Axxon PSIM scheduling tools used to set up time-frames.
  5. Timer is the other Axxon PSIM scheduling tool used to set up time-instances.
  6. Macro event – configuration of is used for configuring the event generation when some interrelated events happen.
  7. Objects link is used for linking objects with cameras.