Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Archive calculation is available only if the Server and Server with viewing client calculation types are selected—see Selecting the type of calculation. Also it is necessary that at least one stream is selected for recording—see Selecting the cameras.

The archive can be calculated with or without RAID.

Calculation of disk space for storing metadata is available only for the Axxon One platform (see Selecting the software platform).

Calculation without RAID

To calculate the disk space without RAID, select No RAID calculation (1).

...

Info
titleNote

Instead of Hours per day, you can use the % of day calculation. To switch, do the following:

  1. Go to Settings, the link is in the top right corner.
  2. Select the in % of day parameter for Set time of archive recording per day.
  3. Click the Save button.

Calculation with RAID

To calculate the disk space with RAID, do the following:

  1. Set the parameters of the archive depth, the average number of hours per day during which it is planned to record into the archive, and the prerecord period, if necessary (1).
    Archive, days—the required archive depth in days.
    Hours per day—the average number of hours per day during which it is planned to record into the archive. 24 hours a day means permanent recording.

  2.  Select the RAID level (2). The following options are available:

    1. JBODsimple consolidation of disks, which is not a RAID level.
    2. RAID-0RAID 0, an array of disks with data striping.
    3. RAID-1 RAID 1, an array of disks with data mirroring.
    4. RAID-10RAID 10, an array of disks with mirroring and striping.
    5. RAID-5—RAID 5, an array of disks with block-level striping and one checksum.
    6. RAID-6RAID 6, an array of disks with block-level striping and two checksums.
  3. Specify the Disk size (3) in the selected units (GB or TB). It is assumed that RAID will be built on the basis of disks of the specified size. The calculation results indicate the required number of disks and other RAID parameters (see Platform calculation results for Server and Server with viewing client).
  4. Specify Maximum number of disks per RAID group (4). Range of available values is specific to the chosen RAID level.
  5. Specify Number of hot spare disks per server (5). Available values are natural numbers in range from 0 up to 100.

    Info
    titleNote

    More detailed information on RAID options can be found on page Description of RAID levels.


Configuring metadata and system log storage

If you select at least one detection tool for cameras (see Selecting the cameras and Types of detection tools (Video Analytics)), then after the video archive parameters step, there will be a step for setting the storage time for metadata and system log:

...