Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Go to the settings panel of the Modbus Input Register object that is created on the basis of the Modbus Device object.
  2. In the Address field (1), enter the Input Register address in the register map of this device.

    Note
    titleAttention!
    • The registers map is provided by the manufacturer.
    • The register address is always less than the register number by 1. The register address is specified in the settings.


  3. From the Format drop-down list (2), select the register data format:
    • Binbinary.
    • Decdecimal.
    • Hexhexadecimal.

      Info
      titleNote

      The Value area (3) displays the current Input Register value in the selected format.


  4. Click the Read value button (4) if it is necessary to read the device register.
  5. Set the Auto update checkbox (5) if it is necessary to automatically read the register values with the interval specified on the Modbus Device object settings panel.
  6. From the Rule drop-down list (6), select the rule to which this Input Register will obey (see Configuring the Modbus Rule).
  7. Set the Value change checkbox (7) if it is not necessary to display the events on the register value change in the Event Viewer.  
  8. Uncheck Clear the Indicator change checkbox (8) if it is necessary to allow displaying the register values in the plain text on the map.

    Note
    titleAttention!

    Value change of this parameter will be applied after restarting the ACFA PSIM Server.


  9. Set the Config event checkbox (9) if it is not necessary to display the events in the Event Viewer when the rule is triggered.
  10. Click the Apply button (10) to save the changes.

...