Table describes the setting parameters corresponding to the elements of the settings panel of the Backup archive panel object.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range | ||
1 | Identification number* | Automatically | Displays the identification number of the Backup archive panel | Sequence of numbers | - | Numbers, letters, periods, hyphen, dash and underscore | -From 1 and above. | Depends on the number of the Backup archive panel objects in the digital video surveillance system with distributed architecture |
2 | Name* | Enter the value into the field | Sets the name of the Backup archive panel object | Latin, Cyrillic and service characters | Backup archive panel | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 | ||
3 | Disable | Set the checkbox | Sets the state of the Backup archive panel object | Boolean type | Clear | Set—the Backup archive panel object is disabled and isn't used Clear—the Backup archive panel object is enabled and used | ||
4 | Display | Select the value from the list | Sets the Display parent object of the digital system with distributed architecture, to which the given Backup archive panel object belongs | Name of the Display objects registered in the system | Name of the Display parent object | Depends on the number of the Display objects in the digital video surveillance system with distributed architecture | ||
5 | Backup archive* | Select the value from the list | Sets a Backup archive, which the Operator will control using the Backup archive panel interface object | Name of the Backup archive objects registered in the system | Backup archive 1 | Depends on the number of the Backup archive objects in the digital video surveillance system with distributed architecture | ||
6 | Fixed position | Set the checkbox | Allows moving the Backup archive panel on the screen using the mouse | Boolean type | Clear | Set—the Backup archive panel cannot be moved Clear—the Backup archive panel can be moved | ||
7 | X | Enter the value into the field (Automatically, if the Fixed position checkbox is set) | Sets the X coordinate in the horizontal axis for the upper left corner of the Backup archive panel on the screen | % of the screen width | Not defined | From 0 to M*100, where M is the number of the installed monitors | ||
8 | Y | Enter the value into the field (Automatically, if the Fixed position checkbox is set) | Sets the Y coordinate in the vertical axis for the upper left corner of the Backup archive panel on the screen | % of the screen height | Not defined | From 0 to M*100, where M is the number of the installed monitors | ||
9 | W | Enter the value into the field (Automatically, if the Fixed position checkbox is set) | Sets the width of the Backup archive panel | % of the screen width | Not defined | From 0 to M*100, where M is the number of the installed monitors | ||
10 | H | Enter the value into the field (Automatically, if the Fixed position checkbox is set) | Sets the height of the Backup archive panel | % of the screen width | Not defined | From 0 to M*100, where M is the number of the installed monitors |
...