Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Event viewer object in the digital video surveillance system with distributed architecture

Sequence of numbers

-

Numbers, letters, periods, hyphen, dash and underscore

-From 1 and above.

Depends on the number of the Event Viewer objects in the digital video surveillance system with distributed architecture

2

Name*

Enter the value into the field

Sets the name of the Event viewer object in the digital video surveillance system with distributed architecture

Latin, Cyrillic and service characters

Event viewer

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

Disable

Set the checkbox

Sets the state (enabled or disabled) of the Event viewer object in the digital video surveillance system with distributed architecture

Boolean type

Clear

Setthe Event viewer object is disabled and isn't used

Clearthe Event viewer object is enabled and used

4

Display

Select the value from the list

Sets the Display parent object of the digital system with distributed architecture, to which the given Event viewer object belongs

Names of the Display objects registered in the system

Name of the Display parent object

Depends on the number of the Display objects in the digital video surveillance system with distributed architecture

The Settings group

5


X

Enter the value into the field

Sets the X coordinate in the horizontal axis for the upper left corner of the window of the Event viewer interface object on the screen

% of the screen width

Not defined

From 0 to M*100, where M is the number of the installed monitors

Y

Enter the value into the field

Sets the Y coordinate in the vertical axis for the upper left corner of the window of the Event viewer interface object on the screen

% of the screen height

Not defined

From 0 to M*100, where M is the number of the installed monitors

6

W

Enter the value into the field

Sets the width of the window of the Event viewer interface object

% of the screen width

Not defined

From 0 to M*100, where M is the number of the installed monitors

H

Enter the value into the field

Sets the height of the window of the Event viewer interface object

% of the screen width

Not defined

From 0 to M*100, where M is the number of the installed monitors

7

Monitor

Select the value from the list

Sets the number of the monitor in the system for which the coordinates are specified

Numbers of the monitors in OS

1

1–16

8The × buttonClick the button

Opens the window to set the Event viewer window size and position using the mouse

---
9Allow movingSet the checkbox

Allows the Operator to change the position of the Event viewer window using the mouse

Boolean typeClear

Set—the Operator can change the position of the Event viewer window

Clear—the Operator cannot change the position of the Event viewer window

10Over all windowsSet the checkbox

Allows displaying the Event viewer window on top of all windows

Boolean typeClear

Set—the Event viewer window is displayed on top of all windows

Clearthe Event viewer window is displayed in the standard mode

11

Show video

Set the checkbox

Allows the Operator to view the events archive initialized by the Event viewer as Record to disk using the Event viewer window


Boolean type

Clear

Set—the Operator can view the events archive using the Event viewer window

Clear—the Operator cannot view the events archive using the Event viewer window

12

Show object on map

Set the checkbox

Allows the Operator to view the objects, displayed in the Event viewer window, on the map


Boolean type

Clear

Set—the Operator can view the objects, displayed in the Event viewer window, on the map

Clear—the Operator cannot view the objects, displayed in the Event viewer window, on the map

13

Show report

Set the checkbox

Allows the Operator to create a printed form of the report and print the information about all events registered by the Event viewer over a specified period of time


Boolean type

Clear

Set—the Operator can creating a printed form of the report and print the information about all events registered by the Event viewer over a specified period of time

Clearthe Operator cannot creat a printed form of the report and print the information about all events registered by the Event viewer over a specified period of time

14

Load protocol

Set the checkbox

Determines if the latest 1000 events registered by the Event viewer with the latest system start, should be downloaded with the start of Intellect

Boolean type

Clear

Setthe latest 1000 events registered by the Event viewer with the latest system start, are downloaded with the start of Intellect

Clearthe latest 1000 events registered by the Event viewer with the latest system start, aren't downloaded with the start of Intellect

15Hide RegionSet the checkboxHides the Region column in the Event viewer windowBoolean typeClear

Setthe Region column isn't displayed

Clearthe Region column is displayed

16Hide CardSet the checkbox

Hides the Card column in the Event viewer window.

See also Card number displaying in the Event viewer window for access events 

Boolean typeClear

Setthe Card column isn't displayed

Clearthe Card column is displayed

17Keep colored after blinkingSet the checkboxSets the highlighting of the alarm messages by the selected color after the blinking stopsBoolean typeClear

Setthe alarm messages are highlighted by the selected color after the blinking stops

Clearthe alarm message isn't highlighted by the selected color after the blinking stops. It is highlighted by the color specified in the filter

The Advanced settings group
18View daysEnter the value into the fieldSets the period over which the events should be displayed in the Event viewer window, if there are more than 10,000 events (or other value set for the Max.number of rows parameter). If there are less events, then all events are displayed regardless of the value of this parameterDays1More than 1
19View eventsSelect the value from the list

Sets the events that should be displayed in the Event viewer window

-all events

all eventsall events are displayed in the Event viewer window

last eventone last event is displayed in the Event viewer window

all last eventsall last events for all selected objects are displayed 

20Max.number of rowsEnter the value into the fieldSets the maximum number of events to display in the Event viewerSequence of numbers100001–50000
21Background colorSelect the value from the list or on the Select color panelSets the background color in the Event viewer windowRGB, CMY or HSLWhiteCorresponds to the standard range of the selected color system
22Text colorSelect the value from the list or on the Select color panelSets the text color in the Event viewer windowRGB, CMY or HSLBlackCorresponds to the standard range of the selected color system
23Color of alarm messagesSelect the value from the list or on the Select color panelSets the color of the alarm message lines in the Event viewer window. To apply the setting, the Duration of blinking, sec parameter should be other than 0RGB, CMY or HSLRedCorresponds to the standard range of the selected color system
24Color of info messagesSelect the value from the list or on the Select color panelSets the color of the information message lines in the Event viewer window. To apply the setting, the Duration of blinking, sec parameter should be other than 0RGB, CMY or HSLBlueCorresponds to the standard range of the selected color system
25Duration of blinking, secEnter the value into the fieldSets the duration of the alarm message blinking in the Event viewer windowsecondsNot definedMore than 0
26Font:<current font>Click the buttonSets the font of the nformation messages in the Event viewer windowStandard Windows Font dialog windowDepends on OS settings-

...