Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the External window object

Sequence of numbers

-

Numbers, letters, periods, hyphen, dash and underscore

-From 1 and above.

Depends on the number of the External window objects

2

Name*

Enter the value into the field

Sets the name of the External window object

Latin, Cyrillic and service characters

External window

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

Disable

Set the checkbox

Sets the state (enabled or disabled) of the External window object 

Boolean type

Clear

Setthe External window object is disabled and isn't used

Clearthe External window object is enabled and used

4

Display

Select the value from the list

Sets the Display parent object, to which the given External window object belongs

Name of the Display objects registered in the system

Name of the Display parent object

Depends on the number of the Display objects

The Settings group

5

X

Enter the value into the field


Sets the X coordinate in the horizontal axis for the upper left corner of the window of the External window interface object on the screen

% of the screen width

Not defined

From 0 to M*100, where M is the number of the installed monitors

6

Y

Enter the value into the field


Sets the Y coordinate in the vertical axis for the upper left corner of the window of the External window interface object on the screen

% of the screen height

Not defined

From 0 to M*100, where M is the number of the installed monitors

7

W

Enter the value into the field

Sets the width of the window of the External window interface object

% of the screen width

Not defined

From 0 to M*100, where M is the number of the installed monitors

8

H

Enter the value into the field

Sets the height of the window of the External window interface object

% of the screen width

Not defined

From 0 to M*100, where M is the number of the installed monitors

9

Monitor

Select the value from the list

Sets the number of monitor which is used to display the window of the third-party application

Number of monitors

1

1–16

10

Attachment

Enter the value into the field

Sets the path to the application, which should be launched.

Note. All windows of the application will be opened simultaneously if the application contains several windows

Latin, Cyrillic and service characters

Not defined

A line containing a sequence of any characters (letters, digits, service characters), case-insensitive.

Number of charactersfrom 1 to 250

11

Thebutton

Click the button

Displays the standard Windows open dialog box to specify the path to the application that you want to run

-

-

-

...