  1. Go to the settings panel of the Virdi Output object that is created on the basis of the Virdi ACU object.
    Image Modified
  2. From the PGM number drop-down list (1), select the output number from 1 to 8.
    Image Added
  3. From the PGM type drop-down list (2), select the output type:
    • Unused - not used.
    • Matching success - is triggered triggers after successful authorization of a user.
    • Matching failed - is triggered triggers after an unsuccessful authorization of a user.
    • Scheduled output - works according to the assigned schedule.
    • Alarm output - is triggered triggers when an alarm is activated.
    • System troubles - is triggered triggers when a problem occurs in the system, for example, a problem with the battery, a problem with the reader, etcand so on.
    • Arm/disarm status - is triggered triggers when a region becomes armed/disarmed.
    • Fire alarm - is triggered triggers when a fire alarm is activated.
    • Silent alarm - is triggered triggers when a silent alarm is activated.
    • Open too long - is triggered triggers when the door is open for too long.
    • Door forced - is triggered triggers when the door is held by force.
  4. In the Param (dep. on type) drop-down list (3):
    • if the output type Matching success or Matching failed output type is selected, then select the door number that will be opened when the corresponding output is triggered: from 1 to 4.
    • if the output type  Alarm output, Fire alarm, or Silent alarm is output type is selected, then select the section number in which the alarm will be triggered when the corresponding output is triggered: from 1 to 4.
    • if the Scheduled output output type Scheduled output is selected, then select the schedule number according to which the corresponding output will operate: from 0 to 255.
  5. From the Activation time drop-down list (4), select the time in seconds within for which the output will be activated: from 0 to 255.
  6. Set the Inverted output check box (5) if checkbox if it is necessary to invert the output.
  7. Click the Apply Image Added button (6) to apply the settings.

...

  1. .