Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Ports 8085 and 8087 are used to connect clients to Web Server 2.0 module.

Info
titleNote.
This data is necessary for setting security system and firewall on the Server. The Corresponding module to which connection is made parameter is set for client-server modules. If there is the “-“ sign in thiscolumn, this means connection to the psim.exe kernel.

...

Monitoring PSIM

Module name

Name of the corresponding object in Axxon PSIM

Connection port

Corresponding module to which connection is made

VIDEOSRV.EXE

IIDK interface

21030

-

VIDEOSRV.EXE

VideoServer

20900

VIDEO.RUN

VIDEOSRV_C.RUNAgent of Control22001

VIDEOSRV_E.RUN

Search in archive

22003

-

VIDEOSRV_M.RUN

Monitoring

22222

-

VIDEOSRV_R.RUN

Monitoring reports

22223

-

VIDEOSRV_S.RUNServer of Control22002
VIDEOSRV.EXEServer of Control7777VIDEOSRV.EXE

STATEUPS.EXE

(UPS operation)

-

8888

VIDEOSRV.EXE

BATDISCH.EXE

(UPS operation)

-

8888

VIDEOSRV.EXE

POWEROFF.EXE

(UPS operation)

-

8888

VIDEOSRV.EXE

POWERON.EXE

(UPS operation)

-

8888

VIDEOSRV.EXE

CentralNetServer.exe

CSC

7755

VIDEOSRV.EXE

forward.runData gateway22327-


Info
titleNote.

If CSC (Central Server of Control) is in use, then between CSC communication server and Server of Control the 20 and 21 TCP ports are used to provide FTP operation. 

...

ACFA PSIM subsystem

Module name

Name of the corresponding object in Axxon PSIM

Connection port

Corresponding module to which connection is made

abc.run

ABC

22031

-

abc_cr.run

ABC control reader *

22235

-

agency_person.run

Visitor Management System

21057

-

aiu.run

"777 ROVALANT" system *

22145

-

aiu3.run

Rovalant  777 ISS *

22217

-

anson.run

Anson ACS *

22267

-

APDA.run

Tempo Reale ACS *

22188

-

apollosdk.run

ApolloSdk

22204

-

Bagulnik2.run

Bagulnik2 *

22195

-

biosmart.run

BioSmart 

22236

-

bolid.run

"Bolid" (COM server)

21025

-

castle.run

Castle server

22183

-

castle_cr.run

CASTLE control reader *

22231

-

chrysantemum.run

PRHK *

22198

-

DB_Import.run

Data import

21022

-

Dunai2.run

Dunai 2 *

22255

-

dunai3.run

Dunai 3 *

22255

-

Elsys.run

Elsys *

22206

-

forsec.run

ForSec *

22166

-

forteza.run

Forteza 

22237

-

Galaxy.run

Galaxy Dimension

22189

-

galaxy2.run

Honeywell ACS/SGPS

22239

-

gate_cr_z2.run

Z2 control reader *

21222

-

Hid.run

VertX / Edge ACS

22220

-

hunter.run

HUNTER PRO SFA

22256

-

intrepid.run

Intrepid Interface Module

22172

-

Intrepid2.run

Intrepid Grunt

22229

-

Intrepid3.run

Intrepid II System

22240

-

keyking.run

KeyKing ACS

22244

-

keywatcher.run

KeyWatcher ACS

22258

-

keywatcher_interface.run

KeyWatcher ACS Interface

22259

-

kodos.run

Kodos server *

22130

-

kodos_cr.run

KODOS control reader *

22155

-

kronverk.run

Kronverk *

22139

-

ksu_cr.run

KSU control reader *

22338

-

legos2.run

"Octagram" ACS/SFA *

22190

-

Magistrator.run

Magistrator *

22161

-

nac.run

"NAC" ACS *

21020

-

nc.run

HoneyWell N1000

21052

-

ncg9.run

Controller NCG-9

22266

-

net.run

"Net" system *

22185

-

nskat.run

SKAT ACS *

22248

-

opc_wrapper.run

OPC Wrapper

22263

-

Optex.run

Optex System

22232

-

orion.run

Bolid (SDK Orion) *

22173

-

paradox.run

Paradox SFA/ACS

22192

-

parsec_pr_x08.run

PR-x08 control reader *

22226

-

Paxton_NET2.run

ACS Paxton NET2

22233

-

pelco.run

PELCO

22234

-

perco.run

"Perco" ACS *

21019

-

PercoS20.run

Perco S20 controller *

22246

-

PhotoIdentification.run

Photo Identification

22163

-

pl.run

Polon Alfa System

22242

-

pnet3.run

ParsecNET 3 ACS/SFA *

22264

-

ravelin.run

Gate Parking ACS

22227

-

RifString.run

RifString system *

22197

-

Rosslare.run

Rosslare ACS *

22203

-

rovalant_a6_a16.run

"ROVALANT (A6, A16)" system *

22165

-

rubeg8_isb.run

Rubeg 8 ISS *

22256

-

rubezh.run

Rubeg SFA *

22261

-

rubicon.run

Rubicon SFA *

22209

-

rusguard.run

"RusGuard" ACS *

22250

-

salto.run

SALTO Server

22208

-

satel.run

"Satel"

21998

-

securiton.run

"Securiton" ACS *

22247

-

sintegral.run

Strelec-Integral SFA *

22257

-

sphinx.run

Sphinx server

22177

-

strelec.run

"Strelec" SFA *

22162

-

topol.run

Topol PSS *

22241

-

trombon.run

Trombone SFA

22224

-

tss2.run

"TSS" ACS/SFA *

22218

-

unipos.run

"UniPos" 7002

22184

-

nipos5xxx.run

UniPos ACFA 5100-5200

22211

-

vers_rs.run

VERS ACS*

22126

-

WorkTime.run

Work Time Accounting

22133

-

xabc.run

Fortecia ACS *

22260

-

zline.run

"ZLine" FSA *

22243

-

account_manager.runAccess Manager22291-
event_manager.runEvent Manager22287-
dsc.run"DSC" FSA22292-
Axxon PSIMToNextBridge.runACFA PSIM − Axxon Smart-card wrapper 22324-
safekey.runSafeKey Panel 22380-
dahua.runDahua22393-
fft.runFFT22289-
risco.runRISCO22399-
onguard.runOnGuard22400-
Symmetry.runSymmetry 22404-
Teltonika.runTeltonika22410-
bosch.run

Bosch APE

22263-
bosch_bis.runBosch BIS22424-
cerberus.run Cerberus ECO controller 22268-
CerberusPro.runCerberusPro22397-
fibersensys.runFiberSensys22388-
aritech.run"Aritech FP2000" FSA22275-
telsap.run"Telsap 2100" FSA22272-
Polon6000.run"Polon6000" FSA22347-
NoderEw2.run"Noder EW2/EWE2" ACS22390-
Esser.run"ESSER by Honeywell" FSA22396-
nedap_aeos.runNedap AEOS22317-
Nitgen.runNITGEN22288-
ansondb.runAnsonDB22270-
rubezh_strazh.runRubezh Strazh *22419-
dozor.runDozor-1A *22147-
fsg.runFSG 22286-
suprema.runSuprema Biometrical ACS22276-
senstar.runSenstar22418-
velocity.runVelocity22274-
abc_2.runController ABC v2 *22353-
intellico.runIntelliko *22411-
sdk_orion.runSDK Orion *22284-
rusguard_2.runRusguard v2 *22363-
perco_cr.runPERCO control reader *21999-
mion.runM-ION *22387-
sphinx_oko.runSphinx Oko Base Unit *22366-
oko.runOko *22359-
lyrix.runLyrix *22385-
pui32.runPUI 32 *22290-
UProxIP400.runUProx IP-400 Server *22392-
keyguard.runKeyGuard System *22421-
orlan.runOrlan System *22398-
raskat.runRaskat System *22283-
axrbc.runRubikon System *22337-
Start7.runStart7 System *22265-
groza.runGroza Detection Tool *22412-
alcoBarrier.runAlcoBarrier *22415-
bas_ip.runBAS-IP22429-
mqtt_broker.runMQTT broker22381-

* These integrations are not included into the English version of ACFA PSIM subsystem and are given here for information only.