Go to documentation repository
Page History
...
Manufacturer | AAM Systems Office address: Kraznokazarmennaya str., 13-402 |
Integration type | SDK |
Equipment Hardware connection | RS-232, IP |
Supported equipmenthardware
Hardware | Function |
---|
Features
AAN-100 | Network controller |
Memory—to 8 MB
Real-time clock—yes
PC connection interfaces: RS232—1 or Ethernet—1
Interfaces for connection with interface modules, security and relay panels: RS485—4 or Ethernet—4
AAN-32S | Network controller |
Memory—to 2 MB
Real time clock—yes
PC connection interfaces: RS232—1
Interfaces for connection with interface modules, security and relay panels: RS485—1 or Ethernet—1
AAN-32N | Network controller |
Memory—to 2 MB
Real time clock—yes
PC connection interfaces: Ethernet—1
Interfaces for connection with interface modules, security and relay panels: RS485—1 or Ethernet—1
AIM-2SL | Access controller |
Central processor—M68HC11 CPU
Memory:
Work storage RAM: 128 KB
EEPROM: 512 kb
Connection interfaces: Wiegand readers—2
Interfaces for connection with interface modules, security and relay panels: RS485—1 or Ethernet—1
AIM-4SL | Access controller |
Memory:
Work storage RAM: 128 kB
EEPROM: 512 kb
Real time clock—yes
Connection interfaces: Wiegand readers—4
Interfaces for connection with interface modules, security and relay panels: RS485—1 or Ethernet—1
AIO-168 | Security panel |
Relay outputs—8
Interfaces of connection to central controller: RS485—1 or Ethernet—1
ASA-72 | Status panel |
Display of alarms, malfunctions, duress, no alarms
Local confirmation of incoming signals
Local reset/check of LEDs
Sound alert for alarms or malfunctions
Support for 72 zones (security panel inputs, reader inputs, etc.)
Interface for connecting to the RS-485 controller
LED to indicate the connection to the controller
4 LEDs to indicate the connection to the controller for each AIO-8/16/168 alarm panel
Tamper sensor
Power failure sensor
Two general purpose alarm inputs
Protection
Licensing
There are four positions in the price-list for one module:
Integration with Apollo (one server) |
Integration with Apollo (one reader) |
Integration with Apollo AIO-168 |
Integration with Apollo (one ASA-72) |
Integration with Apollo (one server) is an electronic guardant key protected protecting Apollo SDK v.2 from from the manufacturer site and storing serial keys of all devices. There is at least one key for system.
If hardware is connected to several servers with Axxon PSIM core coreб then additional purchase of electronic protect keys is required for each second and next servers (Integration with Apollo (one reader). Own configuration for each electronic key— n key—in accordance with settings in the object objects tree of Axxon PSIM.
It is required to present all serial numbers of hardware at the time of module order.
Protection Licensing doesn't depend on number of connected senior panels (AAN-100 and\/or AAN-32). Protection Licensing depends only from number of connected terminals (readers, sensor/relay, ASA-72). It requires is connected with the specifics of module sublicensing in company-manufacturer of module.
Apollo SDK v.2 software module works with AIM-*SL controllers directly. Also there is possibility to work with several AIM-*SL controllers using network controller converter ENI-110.