Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Reverted from v. 179

...

  1. Low-level protocol. The system developer presented events, reactions and equipment connection commands as the byte set, so the equipment can be directly connected to Intellect.
  2. SDKSoftware Development Kit. The system developer presented SDK, so the equipment can be directly connected to Intellect.

  3. Communication server (Program-driver). The system developer presented own driver (program layer between AxxonSoft software and hardware in which events, reactions, configuration commands and state request are built in) in order to connect the equipment. Install the third-party software and configure its interaction with Intellect in order to connect the equipment to Intellect. COM-server and OPC-server are examples of such programs.
  4. APIApplication Programming Interface. The system developer presented an API for working with equipment through the built-in Web server, so the equipment can be directly connected to Intellect.
  5. SOFT-SOFT. The system developer presented an API for using its commands in Intellect and vice versa in order to connect the equipment. Install the full version of third-party software and configure its interaction with Intellect in order to connect the equipment to Intellect. Database synchronization is a way of SOFT-SOFT integration on the level of joint using of one database by two software packages, e.g. to access the event log.

    Info
    titleNote

    Hardware connection interface is not specified for soft-soft integrations because ACFA Intellect connects with 3d party software and not with the devices directly. Please contact the 3d party software vendor in order to get information about the hardware connection interface.


  6. Universal protocol integration: OPC, SNMP, BACnet, and Modbus. OPC and BACnet are industry standards. The system developer makes OPS-server and BACnet-server implementation for its devices and sends data over OPC or BACnet protocols. Intellect is the client for such servers and it gets data (events, reactions, configuration commands, etc.). SNMP is a network protocol used to monitor some devices. The list of some hardware connected to Intellect over universal protocols is specified in the Systems connected by universal protocols section.

  7. Drivers Pack. An equipment was integrated using one of the above methods via Axxon Drivers Pack. When using this integration method, it is necessary to install not only ACFA Intellect (version 6.4 and higher), but also the Drivers Pack (version 3.49 and higher).

...

Common name

Integrated hardware (name of devices)

Functionality

Name in price list

Information on manufacturer

Way of integration

Hardware connection interface

ACFA Intellect version
Noder

EWE4 controller

EE12 controller

EW2 controller

EWE2 controller

Reader MD-R / W

Reader with MDK-R keypad

Expansion board for elevator control IO16RS

Converter RS -> Wiegand

Monitoring, configuration, control

INTELLECT Access Control Service (Noder EW2/EWE2), per controller

INTELLECT Access Control Service (Noder for KONE DCS), per elevator group

INTELLECT Access Control Service (Noder EWE4), per controller

INTELLECT Access Control Service (Noder EE12), per controller


low-level protocolEthernet

6.9.4500

CastlePro, Pro4, RS, ES, EP, EP2, EP4Monitoring, configuration, controlIntellect Access Control Service (Castle), per IP

Castle Creations
540 North Rogers Road
Olathe, Kansas 66062
http://home.castlecreations.com/

communication serverUSB-RS485, Ethernet-
Honeywell N-1000 (past Northern Computers)N-1000Monitoring, controlINTELLECT Access Control Service (Honeywell N-1000-IV), per COMportHoneywell Systems Group
Video and Access Control Solutions
www.security.honeywell.com
low-level protocolRS-232-
SigurEAll Sigur access controllers, including E100, E300H, R500D4/E500D4, R500/E500, E500U/R500U, R900I/E900I, E900U/R900U, E2, E4, etc.Monitoring, configuration, controlINTELLECT Access Control Service (Sphinx), per access controller

«PromAvtomatika Service»
603001, Nizhniy Novgorod, Chernigovskaya street, 17-A, 5th floor.
https://sigursys.com/

SOFT-SOFT--
SALTOCU50ENSVN, GateWay, EncoderMonitoring, configuration, controlINTELLECT SALTO integration moduleSalto
www.saltosystems.com
SOFT-SOFT--
ZK TecoC3-100, C3-200, C3-400Monitoring, configuration, controlINTELLECT Access Control Service (ZKAccess), per door

ZKTeco
Phone: +86 755-33985019
Fax: 12 39 89 901
http://zkteco.su/

SDKEthernet, RS4856.2

Schindler Port

Schindler elevator controllerMonitoring, configurationINTELLECT Access Control Service (Schindler Port), per controller

Schindler Management Ltd
Zugerstrasse 13, 6030 Ebikon, Switzerland
Phone+41 41 445 32 32
https://www.schindler.com

SDKEthernet6.8
Unicard U700 U700 controllerMonitoring, configuration, controlINTELLECT Access Control Service (UNICARD), per access control point

Unicard SA
Phone: 12 39 89 900
Fax: 12 39 89 901
http://www.unicard.pl/

low-level protocolEthernet6.2
AxisA1001Monitoring, controlINTELLECT perimeter security system Integration with (per sensor)Axis Communications AB
Emdalavägen 14
SE-223 69 Lund
Tel.: +46 46 272 18 00
Fax: +46 46 13 61 30
Drivers Pack (ONVIF)Ethernet

ACFA 6.7

DP 3.56

KeyWatcher

KeyWatcherMonitoring, controlINTELLECT Electronic Key Control Service (KeyWatcher), per panel

Morse Watchmans
USA 2 Morse Road Oxford, Connecticut 06478
Phone: 203-264-4949 Toll-free:  800-423-8256
https://www.morsewatchmans.com/

Low-level protocolRS-2326.8
SafeKey

All SafeKey panel models

Monitoring, controlINTELLECT Electronic Key Control Service (SafeKey), per panel

SafeKey
95 04-118, Warszawa, ul. Ostrobramska
+48 22 225 32 10, +48 500 466 588
info@safekey.pl
http://safekey.pl/

Low-level protocolEthernet6.8

STX-1000

All STX series controllers

STX-2200 controller

Monitoring, control
INTELLECT Access Control Service (STX1000), per controller

GS Software
ul. Półłanki 80 lok 402
30-740 Kraków, Poland
Tel.: (+48) 12 444 69 36
www.gs-software.pl

Low-level protocolRS-232, RS-485, Ethernet6.8
SymmetryAmag SymmetryMonitoring, controlINTELLECT Access Control Service (Amag Symmetry), per reader

AMAG Technology, Inc.
USA, 2205 W. 126th Street Unit B Hawthorne, CA 90250
Phone: 1-800-889-9138
https://www.amag.com

SOFT-SOFT-6.9
Nedap AEOSNedap AEOS SoftwareMonitoring, controlINTELLECT Access Control Service (Nedap AEOS Software), per door

Nedap N.V.

Parallelweg 2 7141 DC Groenlo The Netherlands

Tel.: +31 544 471 111

Email: info@nedap.com

https://nedap.com/

SOFT-SOFT-6.9
Bosch BISBosch BIS Software version 4.8Monitoring, configuration, control. The FSA part of Bosch BIS is fully supported via the OPC Wrapper moduleINTELLECT—Bosch BIS ACS integration

Robert Bosch GmbH
Vashutinskoe highway, 24
141400 Khimki, Moscow region
RUSSIA
Phone: +7 495 5609075
Phone: +7 916 3704945
Website: www.bosch.ru
Email: ivan.sergeev@ru.bosch.com

SOFT-SOFT-6.9

...

Common name

Integrated hardware (name of devices)

Functionality

Name in price list

Information on manufacturer

Way of integration

Hardware connection interface

ACFA Intellect version
Paradox

EVO48
EVO192
ACM12

Monitoring, configuration, controlINTELLECT Access Control and Fire Alarm Service (Paradox), per COM portParadox Security Systems 
http://www.paradox.com/
low-level protocolRS-232, USB5.3
FoxSec

FS9000
FS7002PX (MK)
FS7011PX (MK)

Monitoring, configuration, controlINTELLECT Access Control and Fire Alarm Service (Foxsec), per controller

FoxSec 
http://www.foxsec.eu/

low-level protocolEthernet5.2
ApolloSDK v.2

AAN-100
AAN-32S
AAN-32N
AIM-2SL
AIM-4SL
AIO-168
ASA-72
ASP-4 (Monitoring and configuration only)

Monitoring, configuration, controlSee detailed information in the Supported hardware and licensing of the Apollo SDK v.2 integration module section

AAM Systems
Office address: Kraznokazarmennaya str., 13-402
Moscow
Post address: Kraznokazarmennaya str., 14
Moscow, 111250
Tel: +7 (495) 924-2227
Fax: +7 (495) 362-7262
E-mail: aam@aamsystems.ru
www.aamsystems.ru 

SDKRS-232, Ethernet-
HID

EDGE ER40; VertX: v1000, v100, v200, v300, v2000, EVO

Monitoring, configuration, controlINTELLECT Access Control Service (HID VertX/Edge), per readerHID Glogal
http://www.hidglobal.com
SDKEthernet-
OnGuard 7.6Any Access Control, Fire Alarm or Intrusion Panel supported in OnGuard 7.6Monitoring, configuration (users only), control

INTELLECT Access Control and Fire Alarm Service (OnGuard), per reader

INTELLECT Fire Alarm Service (OnGuard), per alarm panel

Lenel S2 https://www.lenel.com/SDKEthernet, RS-2326.9
Honeywell Galaxy Dimension v.2

Galaxy GD-48

Galaxy GD-96

Galaxy GD-264

Galaxy GD-520

DCM

MAX4

Monitoring, configuration, controlINTELLECT Access Control and Fire Alarm Service (Honeywell Galaxy Dimension), per COM portHoneywell Systems Group
Video and Access Control Solutions
Aston Fields Road
Whitehouse Industrial Estate
Runcorn
Cheshire
WA7 3DL
United Kingdom
Tel: +44 (0)8448 000 235
Fax: + 44 (0)01928 754050
Email: sales.video.uk@honeywell.com
www.security.honeywell.com
low-level protocolRS-232, Ethernet5.0

...