Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


Tip

This page describes the setup using the example of receiving video from Axxon One.

Receiving

...

video using the ONVIF-Server module is configured in Axxon

...

One. Information on how to search and add IP devices to Axxon

...

One is described in the Axxon One User Guide.

After adding a camera to Axxon NextOne, in Intellect two ONVIF-Server Profile objects will be created under ONVIF-Server object for each camera added to the corresponding RTSP Server. These objects correspond to video streams of low and high quality in Axxon NextOne.

Info
titleNote

If multistreaming is disabled for the camera, then the parameters of both profiles corresponding to the camera are the same. See Configuration of multistream video.

...

If required it is possible to select the video stream in the Stream dropdown drop-down list. Available video streams areconfigured on the settings panel of the Camera object– see object—see Configuration of multistream video.

When changing camera parameters in Axxon NextOne the corresponding changes will be applied in Intellect too. For instance, if the microphone, analytics, metadata transmission and sensor/relays are enabled in Axxon NextOne, then the corresponding settings are applied for the ONVIF-Server Profile object in Intellect:

  1. PTZ. PTZ object is to be created and configuredin Intellect in order tocontrol PTZ on camera connected via ONVIF-Server on the client. See PTZ configuration section in Installing and configuring security system components guide.
  2. Microphone, Audio stream. Audio card and Microphone objects are to be created and configuredin Intellect in order toreceive and record audio from ONVIF Server on the client. See Configuring audio acquisition from IP devices section in Installing and configuring security system components guide.
  3. Analytics, Metadata. Tracker and VMDA detection objects are to be created and configuredunder the corresponding Camera objectin Intellect in order toreceive and record metadata and analytics data from ONVIF Server on the client. See Configuring smart video detection tools. In Axxon NextOne the ONVIF events detection is to be created for the added camera.
Note
titleImportant!

Changes of the configurationof the RTSP Server object corresponding to the ONVIF Server object in Intellect will be applied in Axxon NextOne only after the Axxon NextOne Server is restarted or when the camera is deleted and added to Axxon NextOne again.

Besides, there are the following checkboxes on the settings panel of the ONVIF-Server Profile object:

  1. Fixed– disables —disables deleting the profile using the driver.
  2. Multicast– enables —enables video transmission in the multicast mode. There are some extra actions besides setting the checkbox checked:
    1. Set the registry key:
      HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\ITV\Intellect\Video\TransportProtocols 
      rtsp = multicast
    2. Enable the multicast mode on the settings panel of the RTSP Server object corresponding to the ONVIF-Server object - see object—see Configuring RTSP Server module.