Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Go to the VT module object settings panel, which is created on the basis of the LPR channel object.
    Image Modified
  2. Set the Zooming checkbox checked to increase the plate recognizing speed on mega-pixel video cameras without loss of recognizing quality (1).

    Info
    titleNote

    This check box is relevant when the value of the Zone width parameter is more than 150 pixels (see Setting up the detection of the LPR channel detector section). The recognizing speed is increasing:

    • 2 times if the value of the Zone width parameter is more than 150 pixels;
    • 4 times if the value of the Zone width parameter is more than 400 pixels;
    • 8 times if the value of the Zone width parameter is more than 800 pixels.


  3. To prevent the loss of processed frames, it is recommended that each megapixel of the video camera be processed in a separate stream. If there is a loss of frames, then it is necessary to increase the number of streams in the Number of streams for frame processing field (2):
    1. If the value of the Number of streams for frame processing field is 0,recognition will be performed in the same stream it was started. It is the default value.

    2. If the value of the Number of streams for frame processing field is 1, recognition will be performed in the parallel stream to the process that starts it. This is the recommended value.

    3. If the value of the Number of streams for frame processing field is 2 or more, recognition will be performed in two or more streams simultaneously to the process that starts it. However, in this case, 1 license channel is used for each stream.

      Note
      titleAttention!

      The specified number of streams should not exceed the number of CPU cores on the Server.


  4. From the License type drop-down list (3) select the type of license used:
    • default - the license type is determined automatically;
    • fast (25 fps);
    • slow (6 fps).

      Note
      titleAttention!

      If you select the license type that is not in the key, then license plate recognition will not work.


  5. Set the Generate unrecognized LP event checkbox (4), if it is necessary to generate NOT DETECTED event for vehicles whose LP was't be recognized.
  6. Perform fine tuning of SDK if required (5) (see VIT VT module object settings panel).

    Note
    titleAttention!

    Fine tuning of SDK is to be performed only with the help of AxxonSoft specialists!


    Info
    titleNote

    The current SDK version can be found by the name of the VIT_<SDK version> folder, for example:

    • for x32: <Auto PSIM installation directory>\Modules\UrmLpr\VIT_2.14.0.
    • for x64: <Auto PSIM installation directory>\Modules64\UrmLpr\VIT_2.14.0.

    Also, the current SDK version can be found using the vpwfetch.exe -v command in the Windows command line, while in the corresponding folder.


  7. Click Apply button (6) to save the changes.

The VIT VT program module is now configured.

Info
titleNote

It is possible to track the disappearance of the recognized number. If the recognized number disappeared from the camera field of view and was not recognized again within the specified time, the lost number event will be generated. To enable this feature, in the VIT.TimeoutLostNumber parameter, set the time in milliseconds after which the lost number event will be generated (for details, see Registry keys reference guide, for more information about working with the registry, see Working with Windows OS registry).

To ensure the operation of this feature, it is necessary to set the True value for the VodiCTL_VPW_DYNAMIC_ENABLE tweaking parameter (see The VT module object settings panel).


Note
titleAttention!

To ensure the proper operation of the VIT program VT program module, it is necessary to grant the read/write access for the current Windows user to the following catalogues and files:

  • <Auto PSIM installation directory>\Modules\UrmLpr\
  • <Auto PSIM installation directory>\Modules64\UrmLpr\
  • C:\ProgramData\VIT\LprPresetDemo\presets.xml