The TELEMETRY_EXT object sends events presented in the table.   Procedure is started when the corresponding event appearsoccurs.

Event

Description of event

Parameter

Description of parameterRange of values

Value range

"KEY_PRESSED"

Key is pressed

param0<>

Code of pressed key

See Installing and configuring security system components guide.

device<>

Device on which key is pressed

0 – Main keyboard 0—AXIS T8312 , main keyboard

1 - AXIS T8313 keyboard

"KEY_RELEASED"

Key is released

param0<>

Code of released key

0..21 for AXIS T8312.

For BOSCH KBD-Digital, BOSCH KBD-Universal and Panasonic WV-CU950 see Installing and configuring security system components guide.

device<>

Device on which key is released

0 – Main keyboard AXIS T8312, main keyboard

1 – Rotary switch AXIS T8313 rotary switch

"MOVED"

Position is changed

param0<>

Bias value

For wheel of JogDial rotary switch  -1.. 1; for wheel of frame-by-frame scrolling Shuttle -7..7

For keyboard Panasonic WV-CU950 JogDial  -1.. 1; Shuttle -6..6

device<>

Type of used control mechanism AXIS T8313

0 wheel of rotary switch,

1 wheel of frame-by-frame scrolling

List of commands and parameters for the TELEMETRY_EXT object is presented in the following table:

Command command description

Parameters

Description

"DRAW_FIGURE" draw a figure on display of of BOSCH KBD-Digital or BOSCH KBD-Universal telemetry panel

display<>

0x00 main display, 0x01 –  status status display

x1<>

Start coordinate on X axis (from 0 to 127 for main display, from 0 to 121 for status display)

y1<>

Start coordinate on Y axis (from 0 to 239 for main display, from 0 to 31 for status display)

x2<>

End coordinate on X axis (from 0 to 127 for main display, from 0 to 121 for status display)

y2<>

End coordinate on Y axis (from 0 to 239 for main display, from 0 to 31 for status display)

is_fill<>

0 do not fill the figure, 1 fill the figure

is_set_pixels<>

0 remove figure from display, 1 draw figure

figure<>

0 line, 1 rectangle

"PRINT_TEXT" print text on display of BOSCH KBD-Digital or BOSCH KBD-Universaltelemetry panel

display<>

0x00 –main main display, 0x01 –  status status display

x<>

Coordinate on X axis (from 0 to 127 for main display, from 0 to 121 for status display)

y<>

Coordinate on Y axis (from 0 to 239 for main display, from 0 to 31 for status display)

charset<>

Coding:

0 Latin

1 Cyrillic

2 Central europeanEuropean

style<>

Style:

0 Normal

1 Semi-bold

text <>

Test message

"PRINT_TEXT" print text on display of Panasonic WV-CU950telemetry panel

y<>

0 display text on the first line

1 display text on the second line

text<>

 Entered  Displayed text of a line, maximum 20 symbolscharacters

flickering<>

Line consists of 6 symbols characters determining parameters of text flashing: d1 d2 d3 d4 d5 d6

d1 determines period of flashing :

0 flashing disabled

1 - period 0.25 sec, symbol character is changed replaced by white space

2 - period 0.5 sec, symbol character is changed replaced by white space

3 - period 0.75 sec, symbol character is changed replaced by white space.

4 - period 1 sec, symbol character is changed replaced by white space.

5 - period 0.25 sec, symbol character is changed replaced by white dark space

6 - period 0.5 sec, symbol character is changed replaced by white dark space

7 - period 0.75 sec, symbol character is changed replaced by white dark space

8 - period 1 sec, symbol character is changed replaced by white dark space

d2: 1 – symbols —characters from 1 to 4 are flashing, 0 these symbols character are not flashing.

d3: 1 – symbols —characters from 5 to 8 are flashing, 0 these symbols characters are not flashing.

d4: 1 – symbols —characters from 9 to 12 are flashing, 0 these symbols are characters are not flashing.

d5: 1 – symbols —characters from 13 to 16 are flashing, 0 these symbols characters are not flashing.

d6: 1 – symbols —characters from 17 to 20 are flashing, 0 these symbols characters are not flashing.

"CLEAR_DISPLAY" clear display of BOSCH KBD-Digital or BOSCH KBD-Universal telemetry panel.

Reaction without parameters for the Panasonic WV-CU950 telemetry panel.

display<>

0x00 main display, 0x01 –  status status display

"RELE_ON" turn on the light on the AXIS T8312 keyboard or Panasonic WV-CU950panelCU950 panel

rele<>

Code of key with the light, 12..16 for AXIS T8312.

For Panasonic WV-CU950 see Installing and configuring security system components guide, section Features of Panasonic WV-CU950 control panel configuration and operation.

"RELE_OFF" turn off the light on the AXIS T8312 keyboard or Panasonic WV-CU950 panel

rele<>

Code of key with the light, 12..16

"RESET" reset of Panasonic WV-CU950 panel

type<>

0 instant reset

1 reset after 100 ms.

2– 2reset after 200 ms.

3– 3reset after 500 ms.

4– 4reset after  after 1 s.

"SET_ALARM" set type of alarm signal of the Panasonic WV-CU950 panel

audio_alarm<>

0 sound OFFis off

1 simple single alarm signal

2 simple double alarm signal

3 simple triple alarm signal

4 single alarm signal lasting 0.1 sec.

5 single alarm signal lasting 0.2 sec.

6 - single alarm signal lasting 0.3 sec.

7 - single alarm signal lasting 1 sec.

8 simple single tone

9 simple double tone

A– Asimple triple tone

B– Bsingle signal lasting 0.1 sec

C– Csingle signal lasting 0.2 sec

D– Dsingle signal lasting 0.3 sec

E– Esingle signal lasting 1 sec

F alarm signal