Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

By default, an operator is forbidden to administer any objects. If an operator is granted access to one or more tabs of the System Settings window, they automatically receive the rights permissions to administer, control and view all system objects on these tabs.

When the operator has the rights permissions for control functions, they can use the buttons, menu items and other interface elements allowing to control the corresponding objects (cameras, microphones, telemetry, event viewer, etc). In addition to overall restriction of object control functions, the separate commands can be prohibited (see Limiting access to sending commands (reactions)).

...

By default, operator can have a full access to administrator,  operator operator and control functions of the objects with the given functions.  It is possible to ban prohibit the operator to administer one or several objects, limit the list of available functions of object control and also limit monitor opportunities.

Info
titleNote

If the administrator password is not set (see Administrator password registration) and the access to the required tabs of the System settings dialog window is limited (see Limiting access to the tabs of the System Settings window), then the limitation of the object configuration rights permissions will not be available.

To limit operator access to the administration of certain objects of Axxon PSIM, do the following:

  1. Open the Users tab in the System Settings window (1).
  2. Open the required User permissions object in the objects tree under the User permissions button (2).
    The settings panel for this object opens on the right side of the System Settings window.

  3. Go to the Objects tab (3). The object tree in corresponds to the lower part permissions of the settings panel represent the rights of the current operator. Checkboxes current Axxon PSIM operator. In the object tree, to the left of the objects indicate and allow changing the administrative, control or viewing rights for these objects. The components of the tree represent the system objects which the current user can administer according to their rights’ settings. Name of marks corresponds to object names, which administration, control and monitoring may be accessible to Operator with proper rights (3).
    Correspondence of mark type to Operator rights each object there is a field that can be edited—it indicates the Operator’s permissions to administer, control, and view system objects. The names of the icons correspond to the names of objects, the administration, control and viewing of which can be available to the Operator with the appropriate permissions. The correspondence of the icon type to the Operator’s permissions is given in the table.

    Type of markIcon

    Right to administer

    Right to control the object

    Right to monitor view the object

    A gray mark

    Yes

    Yes

    Yes

    A green mark  

    No

    Yes

    Yes

    An M mark

    No

    No

    Yes

    A cross mark x

    No

    No

    No

    Info
    titleNote

    The administrative, control or viewing rights permissions to interface objects depend on the rights permissions to the Computer objects. The rights permissions to the Computer object have a higher priority. For example, if the user rights permissions allow the administration of the Display object, but prohibit the administration of the Computer object to which this Display is assigned, then a user logged on to the computer prohibited for administration will not be able to administer the Display object (see also Assigning the displays to the operator workstations).

...


  1. After finishing the setting, click the Apply button(4).

The following hotkeys can be used for objects tree control:

KeyFunction
"+" on the numeric keypadGrants all rights permissions to the selected objects (sets the gray mark)

"-" on the numeric keypad

Forbids the selected object (sets the red cross)
"Space"Sequential change of the rights permissions to the selected object in the direction of increasing (forbidden-monitoring-control-administration and then cyclically).
"Left " and " right " arrowsExpand / collapse the selected tree branch.
"/" on the numeric keypadFully collapse the selected branch of the objects tree
"*" on the numeric keypadFully expand the selected branch of the objects tree
"Shift" + "/" on the numeric keypadFully collapse all branches of the objects tree. This view will be saved for the current user even after Axxon PSIM restart.
"Shift "+ "*" on the numeric keypadFully expand all branches of the objects tree. This view will be saved for the current user even after Axxon PSIM restart.

Expanding and collapsing the tree functions are also available when you right-click on an object in the object tree (see The Expand tree function and The Collapse tree function).

...