Configuring the parameters of the detection tool
To configure the Sitting Person Detection, do the following:
- Create Pose Detection (see Configuring Pose Detection).
- Below the Pose Detection, click Create… → Sitting Person Detection.
By default, the Sitting Person Detection triggers if a sitting person is detected in the specified area.
If necessary, you can change the detection tool parameters. The list of parameters is given in the table:
Parameter | Value | Description |
---|---|---|
Other | ||
Enable | Yes | The detection tool is enabled by default. To disable the detection tool, select the No value |
No | ||
Name | Sitting Person Detection | Enter the detection tool name or leave the default name |
Type | Sitting Person Detection | Name of the detection tool type (non-editable field) |
Basic settings | ||
Number of measurements in a row to trigger detection | 2 | Specify the minimum number of frames with the corresponding pose or behavior for the detection tool to trigger. The value must be in the range [1, 20]. |
To save the parameters of the detection tool, click the Apply button. To cancel the changes, click the Cancel button.
Configuring the frame perspective
...
- In the preview window, click the button.
- Specify the size of the same person in different parts of the frame by eye. To create a leveling rod, left-click the video image to add two anchor points. You must set at least three leveling rods. The size of the leveling rod must be about the average height of a person at this part of the frame. You can resize the rod by stretching its anchor points . You can move it on screen by dragging and dropping.
Note title Attention! When you set up leveling rods, the following conditions must be met:
- the rods that are located at the same distance from the camera lens, must be of the same size;
- the feet of the rods must be located on the same surface (for example, floor);
in complex scenes, we recommend adding more than three rods to increase the accuracy of the detection;
in the parts of the frame where the lens vertical distortion is observed, the rods must be parallel to the nearest vertical objects (for example, door, wardrobe);
- for portrait-oriented scenes (such as corridor, shopping aisle, warehouse aisle, and so on), the arrangement of the rods must form triangles.
Info title Note - For convenience of configuration, you can "freeze" the frame. Click the button. To cancel the action, click this button again.
- The area for detection is displayed by default. To hide it, click the button. To cancel the action, click this button again.
- To delete a rod, click the button.
- Click the Apply button.
Configuring the Sitting Person Detection is complete.