Go to documentation repository
Page History
Configuring the parameters of the detection tool
To configure the Close-standing people detection, do the following:
- Create Pose Detection (see Configuring Pose Detection).
- Below the Pose Detection, click Create… → Close-standing people detection.
...
By default, the Close-standing people detection tool triggers when "skeleton" bounding boxes around individuals people collide.
Info | ||
---|---|---|
| ||
Bounding boxes are not displayed in the interface. They are usually a bit larger than the "skeletons" dimensions. |
If necessary, you can change the detection tool parameters. The list of parameters is given in the table:
Parameter | Value | Description |
---|---|---|
Other | ||
Enable | Yes | The detection tool is enabled by default. To disable the detection tool, select the No value |
No | ||
Name | Close-standing people detection | Enter the detection tool name or leave the default name |
Type | Close-standing people detection | Name of the detection tool type (non-editable field) |
Basic settings | ||
Distance sensitivity | 2 | Specify the distance between people in meters at which the detection tool must trigger. Alarm will be generated if the distance between people in the frame is equal to or less than the specified distance. The value must be in the range [0, 20] |
Leveling rod length | 1.7 | Specify the average height of a person in meters, according to which the leveling rods are set. The value must be in the range [0 3] |
Number of measurements in a row to trigger detection | 4 | Specify the minimum number of frames with close-standing people for the detection tool to trigger. The value must be in the range [1, 100]. Increasing the value can help eliminate false alarms, but increases the risk of skips. Decreasing the value can help reduce skips, but increases the probability of false alarms |
To save the parameters of the detection tool, click the Apply button. To cancel the changes, click the Cancel button.
Configuring the frame perspective
if you want to change the triggering distance, you must configure You can set another triggering distance by adjusting the frame perspective:
Note | ||
---|---|---|
| ||
For portrait-oriented scenes (such as corridor, shopping aisle, warehouse aisle, etc.) perspective adjustment is a must.and so on), we recommend configuring the perspective in any case. |
- In the preview window, click the button.
- Specify
- Select a detection tool, and click the button in the preview window.
- Set the size of the same object in different areas parts of the frame by eye. To create a leveling rod, left-click on the video image and to add two anchor points. Set You must set at least three leveling rods. The size of the leveling rod should must be about the average height of a person at this point in part of the frame. You can resize the rod by stretching its anchor points . You can move can move it on screen by dragging and dropping.
Note title Attention! When
settingyou set up
theleveling rods, the following conditions
shouldmust be met:
The- the rods that are located at the same distance from the
- camera lens,
- must be of the same size
- ;
- the feet of the rods
- must be located on the same surface (
- for example, floor)
- ;
in complex scenes,
we recommend adding more than three rods to increase the accuracy of the detection
;
in the parts of the frame where the lens vertical distortion is observed, the rods
must be parallel to the nearest vertical objects (
for example, door, wardrobe)
;
- for portrait-oriented scenes (such as corridor, shopping aisle, warehouse aisle,
- and so on), the arrangement of the rods
- must form triangles.
Info title Note For your - For convenience of configuration, you can
- "freeze" the frame. Click the button. To cancel the action, click this button again.
Info title Note - The area for detection is displayed by default. To hide it, click the
- button.
- In the Distance sensitivity field (1) enter a triggering distance value in meters between people. The detection tool will trigger if the distance between people in the frame becomes equal or less than the specified value. The value should be in the range [0; 20].
In the Leveling rod length field (2) enter the average height of a person (in meters), according to which the leveling rods are set. The value should be in the range [0; 3].
- Set the minimum number of frames in which the detection tool should detect close-standing people in order to trigger (3). The value should be in the range [1; 100].
...
- To cancel the action, click this button again.
- To delete a rod, click the button.
- Click the Apply button.