To configure the Stop In Area, do the following:
- Create the required detection tool and specify its parameters (see Creating detection tools).
- Below the created detection tool, click Create… → Stop In Area.
By default, the detection tool is enabled and triggers when an object stops moving in the area and remains stationary The detection tool will trigger if an object stops and remains idle for a specified time period.
Info | ||
---|---|---|
| ||
The object doesn't have to be completely idlestationary, minor jitter is permitted. |
To set a specified time period, you must perform the following steps:
slight shaking is allowed. |
If necessary, you can change the detection tool parameters. The list of parameters is given in the table:
Parameter | Value | Description | |||||
---|---|---|---|---|---|---|---|
Other | |||||||
Enable | Yes | The detection tool is enabled by default. To disable the detection tool, select the No value | |||||
No | |||||||
Name | Stop In Area | Enter the detection tool name or leave the default name | |||||
Event hold time (sec) | 2 |
Specify the time period in seconds when events will be held when responding to a group of objects. The value must be in the range [0, 86400] | |||||
Type | Stop In Area | Name of the detection tool type (non-editable field) | |||||
Advanced settings | |||||||
X-axis offset | 15 | Specify the X-axis and Y-axis offsets as a percentage of the track area to set the area of the detection tool triggering. The values must be in the range [1, 50] | |||||
Y-axis offset | 10 | ||||||
Basic settings | |||||||
Maximum object height | 100 | Specify the maximum object height as a percentage of the frame size for the detection tool to trigger. The value must be in the range [0.05, 100].
| |||||
Maximum object width | 100 | Specify the maximum object width as a percentage of the frame size for the detection tool to trigger. The value must be in the range [0.05, 100].
| |||||
Minimum object height | 0.1 | Specify the minimum object height as a percentage of the frame size for the detection tool to trigger. The value must be in the range [0.05, 100].
| |||||
Minimum object width | 0.1 | Specify the minimum object width as a percentage of the frame size for the detection tool to trigger. The value must be in the range [0.05, 100].
| |||||
Number of alarm objects | 2 |
Specify the number of objects that can cause the detection tool triggering. The value must be in the range [1, 100] | |||||
Object class | All classes | Select the object class that must trigger the detection tool. The default value is All classes.
| |||||
Vehicle | |||||||
Person | |||||||
Stop in area duration | 0 | Specify the time in seconds during which the object is stationary for the detection tool to trigger. The value must be in the range |
...
[0, 3600].
|
...
|
...
|
...
|
...
...
|
...
| |||||||
Trigger on group of objects | Yes | The parameter is disabled by default. If you want the detection tool to trigger only for a group of objects, select the Yes value.
| |||||
No |
By default, the entire frame is the detection area. In the preview window, you can specify the detection areas using the anchor points (see Configuring the Detection Zone).
Info | ||
---|---|---|
| ||
|
To save the parameters of the detection tool, click the Apply button. To cancel the changes, click the Cancel button
...
.