Go to documentation repository
Page History
To configure the Multiple Objects, do the following:
- Create the required detection tool and specify its parameters (see Creating detection tools).
- Below the created detection tool, click Create… → Multiple Objects.
By default, the detection tool is enabled and triggers when the number of objects in the detection area exceeds the value specified in the detection tool settings.
If necessary, you can change the detection tool parameters. The list of parameters is given in the table:
Parameter | Value | Description | |||||
---|---|---|---|---|---|---|---|
Other | |||||||
Enable | Yes | The detection tool is enabled by default. To disable the detection tool, select the No value | |||||
No | |||||||
Name | Multiple Objects | Enter the detection tool name or leave the default name | |||||
Type | Multiple Objects | Name of the detection tool type (non-editable field) | |||||
Basic settings | |||||||
Maximum object height | 100 | Specify the maximum object height as a percentage of the frame size for the detection tool to trigger. The value must be in the range [0.05, 100].
| |||||
Maximum object speed | 500 | Specify the maximum object speed per second for the detection tool to trigger. The value must be in the range [0, 500].
| |||||
Maximum object width | 100 | Specify the maximum object width as a percentage of the frame size for the detection tool to trigger. The value must be in the range [0.05, 100].
| |||||
Minimum object height | 0.1 | Specify the minimum object height as a percentage of the frame size for the detection tool to trigger. The value must be in the range [0.05, 100].
| |||||
Minimum object speed | 0 | Specify the minimum object speed per second for the detection tool to trigger. The value must be in the range [0, 500].
| |||||
Minimum object width | 0.1 | Specify the minimum object width as a percentage of the frame size for the detection tool to trigger. The value must be in the range [0.05, 100].
| |||||
Number of alarm objects | 10 | Specify the number of objects for the detection tool to trigger. The value must be in the range [1, 100] |
When configuring the Multiple objects detection tool, you should set the maximum number of objects within the analyzed zone. Exceeding this number leads to triggering the tool.
To configure the detection tool, do the following:
...
. |
...
is exceeded, the detection tool generates the |
...
Triggering start event. When the number of objects becomes less than the specified value, the Triggering end event is generated. | |||||||
Object class | All classes | Select the object class that must trigger the detection tool. The default value is All classes.
| |||||
Vehicle | |||||||
Person |
By default, the entire frame is the detection area. In the preview window, you can specify the detection areas using the anchor points (see Configuring the Detection Zone).
Info | ||
---|---|---|
| ||
|
To save the parameters of the detection tool, click the Apply button. To cancel the changes, click the Cancel button in the zone decreases below the specified value, the End Time of Detection Tool Trigger event is generated.