Go to documentation repository
Page History
Section | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Configuring the parameters of the detection tool
...
By default, the Close-standing people detection triggers generates an event when "skeleton" bounding boxes around people collide.
...
Parameter | Value | Description |
---|---|---|
Other | ||
Enable | Yes | The detection tool is enabled by default. To disable the detection tool, select the No value |
No | ||
Name | Close-standing people detection | Enter the detection tool name or leave the default name |
Type | Close-standing people detection | Name of the detection tool type (non-editable field) |
Basic settings | ||
Distance sensitivity | 2 | Specify the distance between people in meters at which the detection tool must trigger. Alarm will be generate an event. Event is generated if the distance between people in the frame is equal to or less than the specified distance. The value must be in the range [0, 20] |
Leveling rod length | 1.7 | Specify the average height of a person in meters, according to which the leveling rods are set. The value must be in the range [0 3] |
Number of measurements in a row to trigger detection | 4 | Specify the minimum number of frames with close-standing people for the detection tool to triggergenerate an eevent. The value must be in the range [1, 100]. Increasing the value can help eliminate false alarmsevent, but increases the risk of skips. Decreasing the value can help reduce skips, but increases but increases the probability of false alarmsevents |
To save the parameters of the detection tool, click the Apply button. To cancel the changes, click the Cancel button.
Configuring the frame perspective
if you want to change the triggering distance that must generate an event, you must configure the frame perspective:
...
- In the preview window, click the button.
- Specify the size of the same object in different parts of the frame by eye. To create a leveling rod, left-click the video image to add two anchor points. You must set at least three leveling rods. The size of the leveling rod must be about the average height of a person at this part of the frame. You can resize the rod by stretching its anchor points . You can move it on screen by dragging and dropping.
Note title Attention! When you set up leveling rods, the following conditions must be met:
- the rods that are located at the same distance from the camera lens, must be of the same size;
- the feet of the rods must be located on the same surface (for example, floor);
in complex scenes, we recommend adding more than three rods to increase the accuracy of the detection;
in the parts of the frame where the lens vertical distortion is observed, the rods must be parallel to the nearest vertical objects (for example, door, wardrobe);
- for portrait-oriented scenes (such as corridor, shopping aisle, warehouse aisle, and so on), the arrangement of the rods must form triangles.
Info title Note - For convenience of configuration, you can "freeze" the frame. Click the button. To cancel the action, click this button again.
- The area for detection is displayed by default. To hide it, click the button. To cancel the action, click this button again.
- To delete a rod, click the button.
- Click the Apply button.