- Create the required detection tool and specify its parameters (see Configuring detection tools detectors and their sub-toolsdetectors).
- Below the created detection tool, click Create… → Stop In Area.
...
Parameter | Value | Description | |||||
---|---|---|---|---|---|---|---|
Other | |||||||
Enable | Yes | The detection tool is enabled by default. To disable the detection tool, select the No value | |||||
No | |||||||
Name | Stop In Area | Enter the detection tool name or leave the default name | |||||
Event hold time (sec) | 2 |
Specify the time period in seconds when events will be held when responding to a group of objects. The value must be in the range [0, 86400] | |||||
Type | Stop In Area | Name of the detection tool type (non-editable field) | |||||
Advanced settings | |||||||
X-axis offset | 15 | Specify the X-axis and Y-axis offsets as a percentage of the track area to receive events from the specified area. The values must be in the range [1, 40] | |||||
Y-axis offset | 10 | ||||||
Basic settings | |||||||
Maximum object height | 100 | Specify the maximum object height as a percentage of the frame size for the detection tool to generate an event. The value must be in the range [0.05, 100]
| |||||
Maximum object width | 100 | Specify the maximum object width as a percentage of the frame size for the detection tool to generate an event. The value must be in the range [0.05, 100]
| |||||
Minimum object height | 0.1 | Specify the minimum object height as a percentage of the frame size for the detection tool to generate an event. The value must be in the range [0.05, 100]
| |||||
Minimum object width | 0.1 | Specify the minimum object width as a percentage of the frame size for the detection tool to generate an event. The value must be in the range [0.05, 100]
| |||||
Number of alarm objects | 2 |
Specify the number of objects that can cause the detection tool to generate an event. The value must be in the range [1, 100] | |||||
Object class | All classes | Select the object class that must generate an event. The default value is All classes
| |||||
Vehicle | |||||||
Person | |||||||
Stop in area duration | 0 | Specify the time in seconds during which the object is stationary for the detection tool to generate an event. The value must be in the range [0, 3600]
| |||||
Trigger on group of objects | Yes | The parameter is disabled by default. If you want the detection tool to generate an event only for a group of objects, select the Yes value
| |||||